# Chapter 7: Masonry Structures

7.1
Introduction

#### 7.1.1 Scope

This Chapter of the Code covers the design, construction and quality control of
masonry structures.

#### 7.1.2 Definitions

For the purpose of this Chapter, the following definitions shall be applicable.
ACTUAL
DIMENSIONS
The measured dimensions of a designated item; such as a
designated masonry unit or wall used in the structures.
The actual dimension shall not vary from the specified
dimension by more than the amount allowed in the
appropriate standard mentioned in Sec 2.2.4 Chapter 2
Part 5.
BED BLOCK
A block bedded on a wall, column or pier to disperse a
concentrated load on a masonry element.
BED JOINT
A horizontal mortar joint upon which masonry units are
placed.
BOND
Arrangement of masonry units in successive courses to tie
the
masonry
together
both
longitudinally
and
transversely; the arrangement is usually worked out to
ensure that no vertical joint of one course is exactly over
the one in the next course above or below it and there is
maximum possible amount of lap.
BOND BEAM
A horizontal grouted element within masonry in which
reinforcement is embedded.
BUTTRESS
A pier of masonry built as an integral part of wall and
projecting from either or both surfaces, decreasing in
cross-sectional area from base to top and conforming to
the requirement of Sec 4.3.3(c) (ii).
CAVITY WALL
A wall comprising two limbs each built-up as single or
multi-wythe units and separated by a 50-115 mm wide
cavity. The limbs are tied together by metal ties or
bonding units for structural integrity.

CELL
A void space having a gross cross-sectional area greater
than 1000 mm2.
COLLAR JOINT
The vertical, longitudinal, mortar or grouted joints.
COLUMN
An isolated vertical load bearing member the width of
which does not exceed three times the thickness.
CROSS JOINT
A vertical joint normal to the face of the wall.
CROSS-
SECTIONAL AREA
OF MASONRY
UNIT
Net cross-sectional area of masonry unit is the gross
cross-sectional area minus the area of cellular space.
CURTAIN WALL
A non-load bearing self-supporting wall subject to
transverse lateral loads, and laterally supported by
vertical or horizontal structural member where necessary.
FACED WALL
A wall in which facing and backing of two different
materials are bonded together to ensure common action
under load.
GROUT
A mixture of cementitious materials and aggregate to
which water is added such that the mixture will flow
without segregation of the constituents.
GROUTED
HOLLOW-UNIT
MASONRY
That form of grouted masonry construction in which
certain designated cells of hollow units are continuously
filled with grout.
GROUTED
MULTI-WYTHE
MASONRY
That form of grouted masonry construction in which the
space between the wythes is solidly or periodically filled
with grout.
HOLLOW UNIT
A masonry unit of which net cross-sectional area in any
plane parallel to the bearing surface is less than 75
percent of its gross cross-sectional area measured in the
same plane.
JAMB
Side of an opening in wall.
HEAD JOINT
The mortar joint having a vertical transverse plane.
LATERAL
SUPPORT
A support which enables a masonry element to resist
lateral load and/or restrains lateral deflection of a
masonry element at the point of support.
LIMB
Inner or outer portion of a cavity wall.
LOAD BEARING
WALL
A wall designed to carry an imposed vertical load in
addition to its own weight, together with any lateral load.

MASONRY
An assemblage of masonry units properly bonded
together with mortar.
MASONRY UNIT
Individual units, such as brick, tile, stone or concrete
block, which are bonded together with mortar to form a
masonry element such as walls, columns, piers, buttress,
etc.
NOMINAL
DIMENSIONS
Specified dimensions plus the thickness of the joint with
which the unit is laid.
PANEL WALL
An exterior non-load bearing wall in framed structure,
supported at each storey but subject to lateral loads.
PARTITION
WALL
An interior non-load bearing wall, one storey or part
storey in height.
PIER
A projection from either or both sides of a wall forming an
integral part of the wall and conforming to the
requirement of Sec 7.4.3.3 of this Chapter.
PILASTER
A thickened section forming integral part of a wall placed
at intervals along the wall, to increase the stiffness of the
wall or to carry a vertical concentrated load. Thickness of
a pier is the overall thickness including the thickness of
the wall or, when bounded into a limb of cavity wall, the
thickness obtained by treating that limb as an
independent wall.
PRISM
An assemblage of masonry units bonded by mortar with
or without grout used as a test specimen for determining
properties of masonry.
REINFORCED
MASONRY
The masonry construction, in which reinforcement acting
in conjunction with the masonry is used to resist forces
and is designed in accordance with Sec 7.6 of this Chapter.
SHEAR WALL
A load bearing wall designed to carry horizontal forces
acting in its own plane with or without vertical imposed
loads.
SOLID UNIT
A masonry unit whose net cross-sectional area in any
plane parallel to the bearing surface is 75 percent or more
of the gross cross-sectional area in the same plane.
SPECIFIED
DIMENSIONS
The dimensions specified for the manufacture or
construction of masonry, masonry units, joints or any
other components of a structure. Unless otherwise stated,
all calculations shall be made using or based on specified
dimensions.

STACK BOND
A bond in bearing and nonbearing walls, except veneered
walls, in which less than 75 percent of the units in any
transverse vertical plane lap the ends of the units below a
distance less than one-half the height of the unit, or less
than one-fourth the length of the unit.
VENEERED WALL  A wall in which the facing is attached to the backing but
not so bonded as to result in a common action under load.
WALL JOINT
A vertical joint parallel to the face of the wall.
WALL TIE
A metal fastener which connects wythes of masonry to
each other or to other materials.
WYTHE
Portion of a wall which is one masonry unit in thickness.

#### 7.1.3 Symbols and Notation

The following units shall be generally implicit in this Chapter for the
corresponding quantities:

Lengths

mm

Areas

mm2

Moment of inertia
mm4

Force

N

Moment, torsion

N mm

Stress, strength

N/mm2
-1
==

Cross-sectional area of anchor bolt
-!
==

Effective area of masonry
-U
==

Gross area of wall
-fM
===

Net area of masonry section bounded by wall thickness and
length of section in the direction of shear force considered
-\\
===

Area of tension (pullout) cone of an embedded anchor bolt
projected into the surface of masonry
-
==

Effective cross-sectional area of reinforcement in a flexural
member
-M
==

Area of steel required for shear reinforcement perpendicular to
the longitudinal reinforcement

# -r

Effective cross-sectional area of compression reinforcement in a
flexural member
,
==

Allowable tension force on anchor bolt
,M
==

Computed shear force on anchor bolt
w
==

Masonry shear strength coefficient
f
==

Modulus of elasticity of masonry

==

Modulus of elasticity of steel
ƒ
=

Loads due to weight and pressure of fluids or related moments
and forces
ƒ\{
===

Allowable average axial compressive stress for centroidally
applied axial load only
ƒ1
==

Allowable flexural compressive stress if members were carrying
bending load only
ƒ1
===

Allowable bearing stress
ƒ
==

Allowable stress in reinforcement
ƒ
===

Allowable compressive stress in column reinforcement
ƒ
==

Allowable flexural tensile stress in masonry
ƒM
==

## Allowable shear stress in masonry

\=
Shear modulus of masonry
…
=

Actual height between lateral supports
…r
==

Height of opening
•
=

Moment of inertia about the neutral axis of the cross-sectional
area
•U, •
=======

Gross, cracked moment of inertia of the wall cross-section
‹
=

Actual length of wall
p
=

Design moment
p
==

Moment capacity of the compression steel in a flexural member
about the centroid of the tensile force
p
===

Cracking moment strength of the masonry wall
pf
==

The moment of the compressive force in the masonry about the
centroid of the tensile force in the reinforcement

# ph

Nominal moment strength of the masonry wall
p
==

The moment of the tensile force in the reinforcement about the
centroid of the compressive force in the masonry
p!
====

Service moment at the mid-height of the panel, including P-Delta
effects
pk
==

Factored moment
Ž
=

Design axial load
Ž\{
===

Allowable centroidal axial load for reinforced masonry columns
Ž1
==

Nominal balanced design axial strength
Ž\`
===

Load from tributary floor or roof area
Žo
==

Nominal axial load strength with bending
Žk
==

Factored axial load
Žk\`
====

Factored load from tributary floor or roof loads
Žk^
===

Factored weight of the wall tributary to the section under
consideration
Ž^
==

Weight of the wall tributary to the section under consideration
.
=

Section modulus
্থ
==

Total design shear force
্থভ
===

Nominal shear strength provided by masonry
্থয
===

Nominal shear strength
্থ
===

# Nominal shear strength provided by shear reinforcement

Depth of equivalent rectangular stress block for strength design
y
=

Effective width of rectangular member or width of flange for T
and I section
y
==

Computed tension force on anchor bolt
yM
==

Allowable shear force on anchor bolt
y^
==

Width of web in T and I member
\$
==

# Distance from the neutral axis to extreme fibre

Distance from the compression face of a flexural member to the
centroid of longitudinal tensile reinforcement

\=
Diameter of the reinforcing bar, diameter of bolt
•
=

Eccentricity of Žk
•fk
===

Maximum usable compressive strain of masonry
\{
===

Computed axial compressive stress due to design axial load
1
==

Computed flexural stress in the extreme fibre due to design
bending load only
fw
===

Computed compressive stress in masonry due to dead load only

==

Modulus of rupture

==

Computed stress in reinforcement due to design load

==

Tensile yield stress of reinforcement
M
==

Computed shear stress due to design load
fr
===

Specified compressive strength of masonry at the age of 28 days
ℎ
=

Height of wall between points of support
ℎr
==

Effective height of a wall or column
/
=

Ratio or distance between centroid of flexural compressive force
and centroid of tensile forces to depth, 0
\*
==

Ratio of depth of the compression zone in flexural member to
depth, d; stiffening coefficient
ে
=

Length of a wall or segment
‡1
==

Embedment depth of anchor bolt
১ে!
===

Anchor bolt edge distance, the least length measured from the
edge of masonry to the surface of the anchor bolt
‡w
==

Required development length of reinforcement
•
=

Modular ratio =  f
⁄
দ্১
===

Ratio of the area of bars cut off to the total area of bars at the
section

\=
Spacing of stirrups or bent bars in a direction parallel to that of
the main reinforcement
›
=

Effective thickness of a wythe, wall or column

# ¬

Bond stress per unit of surface area of bar
∆k
==

Horizontal deflection at mid-height under factored load; P-Delta
effects shall be included in deflection calculation
Σo
==

Sum of the perimeters of all the longitudinal reinforcement

\=
Steel ratio = - y0
⁄

# h

Ratio of  distributed shear reinforcement on a plane
perpendicular to the plane of -fM
•
=

Strength reduction factor.
7.2
Materials
7.2.1
General
All materials used in masonry construction shall conform to the requirements
specified in Part 5 of this Code.  If no requirements are specified for a material,
quality shall be based on generally accepted good practice, subject to the
approval of the building official.
7.2.2
Masonry Units
The following types of masonry units which conform to the standards
mentioned in Sec 2.2.4 of Part 5 may be used in masonry construction:
(a) Common building clay bricks
(b) Burnt clay hollow bricks
(c) Burnt clay facing bricks
(d) Hollow concrete blocks
Other types of masonry units conforming to Sec 2.2.4 of Part 5 may also be used.
7.2.3
Mortar and Grout
Mortar and grout for masonry construction shall conform to the requirements
specified in Part 5 of this Code. Mix proportions and compressive strength of
some commonly used mortars are given in Table 6.7.1.

7.3
Allowable Stresses
7.3.1
General
Stresses in masonry shall not exceed the values given in this Section. All
allowable stresses for working stress design may be increased one third when
considering wind or earthquake forces either acting alone or combined with
vertical loads. No increase shall be allowed for vertical loads acting alone.
7.3.2
Specified Compressive Strength of Masonry, 1
r
The allowable stresses for masonry construction shall be based on the value of
fr
as determined by Sec 7.3.3 below.
Table 6.7.1: Mix Proportion and Strength of Commonly used Mortars
Grade of
Mortar
Mix Proportion by Volume 1, 2
Minimum Compressive Strength at
28 days, N/mm2

Cement
Sand

M1
M2
M3
M4
M5
M6
7.5
Sand and cement shall be measured in loose volume and sand shall be well
graded with a minimum F.M. of 1.20
Lime to a maximum of one fourth (1/4) part by volume of cement may be
used to increase workability.
7.3.3
Compliance with 1
r
Compliance with the requirements for the specified compressive strength of
masonry, fr shall be in accordance with the following:

##### 7.3.3.1 Masonry Prism Testing: The compressive strength of masonry based on

tests at 28 days in accordance with "Standard Test Method for Compressive
Strength of Masonry Prisms", (ASTM E447)  for each set of prisms shall equal or
exceed fr . Verification by masonry prism testing shall meet the following :
(a) Testing Prior to Construction: A set of five masonry prisms shall be
built and tested in accordance with ASTM E447 prior to the start of
construction. Materials used for prisms shall be same as used in the
project. Prisms shall be constructed under the observation of the
engineer or an approved agency and tested by an approved agency.

(b) Testing During Construction: When full allowable stresses are used in
design, a set of three prisms shall be built and tested during
construction in accordance with (ASTM E447) for each 500 square
meters of wall area, but not less than one set of three masonry prisms
for any project. No testing during construction shall be required
when 50% of the allowable stresses are used in design.
7.3.4
Quality Control
Quality control shall include, but not be limited to assure that:

(a) Masonry units, reinforcement, cement, lime, aggregate and all other
materials meet the requirements of the applicable standard of quality
and that they are properly stored and prepared for use.
(b) Mortar and grout are properly mixed using specified proportions of
ingredients. The method of measuring materials for mortar and grout
shall be such that proportions of materials are controlled.
(c) Construction details, procedures and workmanship are in accordance
with the plans and specification.
(d) Placement, splices and bar diameters are in accordance with the
provisions of this Chapter and the plans and specifications.
7.3.5
Allowable Stresses in Masonry
When the quality control provisions specified in Sec 7.3.4 above do not include
requirements for special inspection, the allowable design stresses in this Section
shall be reduced by 50 percent.
(a) Axial Compressive Stress
(i)
Unreinforced masonry walls, columns and reinforced masonry
wall
ƒ\{ =
`×Å
¾1 −¸
ZÅ
îq¼
½
¿
(6.7.1)
(ii) Reinforced masonry columns
ƒ&#123; = Ì
`×Å
\+
ß&
.ßÁ ƒÓ ¾1 −¸
ZÅ
îq¼
½
¿
(6.7.2)
(b) Compressive Stress in Flexural
ƒ1 = 0.33fr ≤  10 N/mmq
(6.7.3)

(c) Tensile Stress of Walls in Flexure
The allowable tensile stress for walls in flexure of masonry structures
without tensile reinforcement using mortar Type M1 or M2 shall not exceed
the values specified in Tables 6.7.2 and 6.7.3. For Types M3 and M4 mortar,
the values shall be reduced by 25 percent.
No tension is allowed across head joints in stack bond masonry. Values for
tension normal to head joints are for running bond. These values shall not
be used for horizontal flexural members such as beams, girders or lintels.
Table 6.7.2: Flexural Tension, Ft
Masonry
Normal to Bed Joints
N/mm2
Normal to Head Joints
N/mm2
Solid Units
0.20
0.40
Hollow Units
0.12
0.25
Table 6.7.3: Tension Normal to Head Joints, Ft
Masonry
Clay Units
N/mm2
Concrete Units
N/mm2
Solid Units
0.35
0.40
Hollow Units
0.22
0.25
(d) Reinforcing Bond Stress, u
Plain Bars:

### 0.30 N/mm2

Deformed Bars: 1.0 N/mm2
(e) Shear Stress for Flexural Members, ƒM
(i) When no shear reinforcement is used

ƒM = 0.083fr   ≤0.25 N/mm2
(6.7.4)
(ii) When shear reinforcement  is designed to take entire shear force
ƒM = 0.25fr   ≤0.75  N/mm2
(6.7.5)
(f) Shear Stress for Shear Walls, ƒM
(i) Unreinforced masonry
For clay units:
ƒM = 0.025fr   ≤0.40  N/mm2
(6.7.6)

For concrete units:

M1 or M2 Mortar:

### 0.20 N/mm2

M3 Mortar:

### 0.12 N/mm2

(ii) The allowable shear stress for reinforced masonry shear walls shall be
according to Table 6.7.4.
Table 6.7.4: Allowable Shear Stress for Reinforced Masonry Shear Walls, 4

Masonry Wall
M/Vd
Fv, N/mm2
Maximum Allowable N/mm2
Masonry
taking all
shear
« 1
36 Ì4 −p
্থ০" ভৎ
Ì0.4 −0.2 p
্থ০"
≥ 1
0.083fr
0.17
Reinforcement
taking all
shear
« 1
24 Ì4 −p
্থ০" ভৎ
Ì0.6 −0.2 M
VdÓ
≥ 1
0.125fr
0.37
7.3.6
Allowable Stresses in Reinforcement
(a) Tensile Stress
(i) Deformed bars,
ƒ = 0.5   ≤165  N/mm2
(6.7.7)

(ii)   Ties, anchors and plain bars,
ƒ = 0.4   ≤135  N/mm2
(6.7.8)
(b) Compressive Stress
(i) Deformed bars in columns and shear walls,
ƒ = 0.4   ≤165  N/mm2
(6.7.9)

(ii) Deformed bars in flexural members
ƒ = 0.5   ≤165  N/mm2
(6.7.10)

7.3.7
Combined Compressive Stress
Members subject to combined axial and flexural stresses shall be designed in
accordance with accepted principles of mechanics or in accordance with the
following formula:
`»
5» +
`
5 ≤1
(6.7.11)

7.3.8
Modulus of Elasticity
The modulus of elasticity of masonry shall be determined by the secant method.
The slope of the line connecting the points 0.05fr  and 0.33fr on the stress-
strain curve shall be taken as the modulus of elasticity of masonry. If required,
actual values shall be established by tests. These  values  are  not  to  be  reduced
by  50  per  cent  as  specified  in Sec 7.3.5(a).
(a) Modulus of Elasticity for Masonry
f = 750fr ≤15,000  N/mm2
(6.7.12)
(b) Modulus of Elasticity for Steel
 = 2,00,000  N/mm2
(6.7.13)
(c) Shear Modulus of Masonry

* \= 0.4f  N/mm2
  (6.7.14)
  7.3.9
  Shear and Tension on Embedded Anchor Bolts

##### 7.3.9.1 Allowable  loads and  placement requirements for anchor bolts shall be

in accordance with the following:
(a) Bent bar anchor bolts shall have a hook with a 90o bend with an inside
diameter of 301 plus an extension of 1.501 at the free end.
(b) Headed anchor bolts shall have a standard bolt head.
(c) Plate anchor bolts shall have a plate welded to the shank to provide
anchorage equivalent to headed anchor bolts.
৭.৩.৯.২ ঞযব বভভবপঃরাব বসনবফসবহঃ ষবহমঃয, ১ে ভড়ৎ নবহঃ নধৎ ধহপযড়ৎং ংযধষষ নব:যব
length of embedment measured perpendicular from the surface of the masonry
to the bearing surface of the bent end minus one anchor bolt diameter. For plate
ড়ৎ যবধফবফ ধহপযড়ৎ নড়ষঃং ১ে ংযধষষ নব:যব ষবহমঃয ড়ভ বসনবফসবহঃ সবধংঁৎবফ
perpendicular from the surface of the masonry to the bearing surface of the
plate or head of the anchorage. All bolts shall be grouted in place with at least 25
mm of grout between the bolt and the masonry except that 6 mm diameter bolts
may be placed in bed joints which are at least twice as thick as the diameter of
the bolt.
7.3.9.3
Allowable shear force
Allowable loads in shear shall be according to Table 6.7.5 or lesser of the value
obtained from the following formulae:
,M = 1070(fr -1)/î
(6.7.15)
,M = 0.12-1
(6.7.16)

ডযবহ:যব ফরংঃধহপব ে নব রং ষবংং:যধহ ১২ফন,:যব াধষঁব ড়ভ,গ রহ ঊয়. ৬.৭.১৫ ংযধষষ নব
ৎবফঁপবফ:ড় ুবৎড় ধঃ ধ ফরংঃধহপব ১ে! বয়ঁধষ:ড় ৪০ সস. ডযবৎব ধফলধপবহঃ ধহপযড়ৎং ধৎব
spaced closer than 801, the allowable shear of the adjacent anchors determined
by Eq. 6.7.15 shall be reduced by interpolation to 0.75 times the allowable shear
value at a centre to centre spacing of  401.
7.3.9.4
Allowable tension
Allowable tension shall be the lesser value selected from Table 6.7.6 and Table

#### 6.7.7 or shall be determined from lesser of the values obtained from the

following formulae:
, = 0.04-\fr
(6.7.17)
, = 0.2-1
(6.7.18)
The area -\ shall be the lesser of the area obtained from Equations 6.7.17 and

#### 6.7.18 and where the projected areas of adjacent anchor bolts overlap, -\ of

each anchor bolt shall be reduced by 50 percent of the overlapping area.
-\ = 6‡1
q
(6.7.19)
-= ৬১ে!
q
(6.7.20)
Table 6.7.5: Allowable Shear, Bv for Embedded Anchor Bolts for Masonry, kN\*

Bent Bar Anchor Bolt Diameter, mm
1
r
N/mm2
2.0
3.7
5.9
7.9
8.5
9.1
9.6
2.0
3.7
5.9
8.2
8.3
9.5
10.1
2.0
3.7
5.9
8.5
9.2
9.8
10.4
2.0
3.7
5.9
8.5
9.7
10.3
11.0
2.0
3.7
5.9
8.5
10.1
10.8
11.5
2.0
3.7
5.9
8.5
10.9
11.6
12.3

* Values are for bolts of at least ASTM A307 quality. Bolts shall be those specified in Sec 4.3.9.1.

Table 6.7.6:  Allowable Tension, 7 for Embedded Anchor Bolts for Masonry, kN1, 2

Embedment Length  , or Edge Distance, 8 mm
fr
N/mm2
1.0
2.4
4.3
6.7
9.7
17.3
27.0
1.2
2.6
4.7
7.4
10.6
18.9
29.6
1.2
2.8
5.0
7.8
11.2
20.0
31.2
1.3
3.1
5.6
8.7
12.6
22.4
35.0
1.5
3.4
6.7
9.5
13.8
24.5
38.2
1.7
3.9
7.0
11.0
15.9
28.3
44.1
The allowable tension values are based on compressive strength of masonry
assemblages. Where yield strength of anchor bolt steel governs, the allowable
tension is given in Table 6.7.7.
Values are for bolts of at least ASTM A307 quality. Bolts shall be those
specified in Sec 7.3.9.1.
Table 6.7.7: Allowable Tension, 7 for Embedded Anchor Bolts for Masonry, kN1
Bent Bar Anchor Bolt  Diameter, mm
1.5
3.5
6.2
9.8
14.1
19.2
25.1
31.8
1 Values are for bolts of at least ASTM A307 quality. Bolts shall be those specified in Sec 7.3.9.
7.3.9.5
Combined shear and tension
Anchor bolts subjected to combined shear and tension shall be designed in
accordance with the formula given below:
1#
9# +
1÷
9÷ ≤1.00
(6.7.21)
7.3.9.6
গরহরসঁস বফমব ফরংঃধহপব, ১ে!
ঞযব সরহরসঁস াধষঁব ড়ভ ১ে! সবধংঁৎবফ ভৎড়স:যব বফমব ড়ভ:যব সধংড়হৎু ঢ়ধৎধষষবষ:ড়
the anchor bolt to the surface of the anchor bolt shall be 40 mm.

7.3.9.7
Minimum embedment depth, ‡1
ঞযব সরহরসঁস বসনবফসবহঃ ফবঢ়ঃয ১ে ংযধষষ নব ৪ফন নঁঃ হড়ঃ ষবংং:যধহ ৫০ সস.
7.3.9.8
Minimum spacing between bolts
The minimum centre to centre spacing between anchors shall be 401.

#### 7.3.10 Load Test

For load test, the member shall be subject to a superimposed load equal to twice
the design live load plus one-half of the dead load. This load shall be maintained
for a period of 24 hours. If, during the test or upon removal of the load, the
member shows evidence of failure, such changes or modifications as are
necessary to make the structure adequate for the rated capacity shall be made;
or where possible, a lower rating shall be established. A flexural member shall
be considered to have passed the test if the maximum deflection at the end of
ঃযব ২৪ যড়ঁৎ ঢ়বৎরড়ফ হবরঃযবৎ বীপববফং ০.০০৫ে হড়ৎ ০.০০০২৫ য়ে/ন্ ধহফ:যব নবধস ধহফ
slabs show a recovery of at least 75 percent of the observed deflection within 24
hours after removal of the load.

#### 7.3.11 Reuse of Masonry Units

Masonry units may be reused when clean, unbroken and conforms to the
requirements of Part 5. All structural properties of masonry of reclaimed units,
especially adhesion bond, shall be determined by approved test. The allowable
working stress shall not exceed 50 percent of that permitted for new masonry
units of the same properties.
7.4
Basic Design Requirements
7.4.1
General
Masonry structures shall be designed according to the provisions of this Section.
The required design strengths of masonry materials and any special
requirements shall be specified in the plan submitted for approval.
7.4.2
Design Considerations

##### 7.4.2.1 Masonry structures shall be designed based on working stress and

linear stress-strain distribution. Requirements for working stress design of
unreinforced and reinforced masonry structures are provided in Sections 4.5
and 4.6 respectively. In lieu of the working stress design method, slender walls
and shear walls may be designed by the strength design method specified in
Sec 7.7.

The structure shall be proportioned such that eccentricity of loading on the
members is as small as possible. Eccentric loading shall preferably be avoided
by providing:
(a) adequate bearing of floor/roof on the walls
(b) adequate stiffness in slabs, and
(c) fixity at the supports.
7.4.2.2
Effective height
(a) Wall: The effective height of a wall shall be taken as the clear height
between the lateral supports at top and bottom in a direction normal
to the axis considered. For members not supported at the top normal
to the axis considered, the effective height is twice the height of the
member above the support. Effective height less than the clear height
may be used if justified.
(b) Column:  Effective height of the column shall be taken as actual height
for the direction it is laterally supported and twice the actual height
for the direction it is not laterally supported at the top normal to the
axis considered.
(c) Opening in Wall: When openings occur in a wall such that masonry
between the openings is by definition a column, effective height of
masonry between the openings shall be obtained as follows:
(i)
When wall has full restraint at the top, effective height for the
direction perpendicular to the plane of wall equals 0.75… plus
0.25…r, where … is the distance between supports and …r is the
height of the taller opening; and effective height for the
direction parallel to the wall equals ….
(ii) When wall has partial restraint at the top and bottom, effective
height for the direction perpendicular to the plane of wall
equals … when height of neither opening exceeds 0.5… and it is
equal to 2… when height of any opening exceeds0.5…; and
effective height for the direction parallel to the plane of the wall
equals 2….
7.4.2.3
Effective  length
Effective length of a wall for different support conditions shall be as given in
Table 6.7.8.
7.4.2.4
Effective thickness
The effective thickness of walls and columns for use in the calculation of
slenderness ratio, shall be defined as follows:
(a)  Solid Walls: The effective thickness of solid walls, faced walls or
grouted walls shall be the specified thickness of the wall.

(b)  Solid Walls with Raked Mortar Joints: The effective thickness of solid
walls with raked mortar joints shall be the minimum thickness
measured at the joint.
(c) Cavity Walls: When both limbs of a cavity wall are axially loaded,
each limb shall be considered independently and the effective
thickness of each limb shall be determined as in (a) or (b) above. If
one of the limbs is axially loaded, the effective thickness of the cavity
wall shall be taken as the square root of the sum of the squares of the
effective thicknesses of the limbs.
(d) Walls Stiffened by Pilasters: When solid or cavity walls are stiffened
by pilasters at intervals, the effective thickness to be used for the
calculation of ℎr/›  ratio shall be determined as follows:
(i)
Solid Walls: For stiffened solid walls the effective thickness shall
be the specified thickness multiplied by the stiffening
coefficient, k, values of which are given below:
:/ö:
Stiffening Coefficient, k\*
:/ö = !
:/ö =
:/ö = 
1.0
1.4
2.0
1.0
1.3
1.7
1.0
1.2
1.4
1.0
1.1
1.2
20 or more
1.0
1.0
1.0

* Linear interpolation is permitted for obtaining intermediate values of k

Where,
\=ে পবহঃৎব:ড় পবহঃৎব ংঢ়ধপরহম ড়ভ ঢ়রষধংঃবৎং
›\ = thickness of pilaster including the wall
›^ = specified thickness of main wall
\ = width of pilaster in the direction of wall
(ii) Cavity Walls: When one or both limbs of a cavity wall are
adequately bonded into pilasters at intervals, the effective
thickness of each limb shall be determined separately as in (a),
(b) or d above and the effective thickness of the stiffened cavity
wall shall be determined in accordance with (c) above.
Where slenderness ratio of the wall is based on the effective
length, the effective thickness shall be the same as that without
pilasters.
(e) Columns: The effective thickness for rectangular columns in the
direction considered is the actual thickness provided in that
direction. The effective thickness for nonrectangular columns is the
thickness of a square column with the same moment of inertia about
its axis as that about the axis considered in the actual column.

|  /ö<br />: :                            | Stiffening Coefficient, k\*                                                                                                       |
| ---------------------------------------- | --------------------------------------------------------------------------------------------------------------------------------- |
| :/ö:                                    | :/ö = !<br />:/ö = <br />:/ö =                                                                                             |
| 6<br />8<br />10<br />15<br />20 or more | 1.0<br />1.4<br />2.0<br />1.0<br />1.3<br />1.7<br />1.0<br />1.2<br />1.4<br />1.0<br />1.1<br />1.2<br />1.0<br />1.0<br />1.0 |

Table 6.7.8: Effective Length of Walls
Support Condition
Effective Length
Where a wall is continuous and is supported by cross wall and there is no
opening within a distance of H/8 from the face of cross wall. OR,
Where a wall is continuous and is supported by pier/buttresses
conforming to Sec 7.4.3.3 (c).
0.8‹
Where a wall is supported by cross wall at one end and continuous with
cross wall at other end. OR,
Where a wall is supported by pier/buttresses at one end and continuous
with pier/buttresses at other end conforming to Sec 7.4.3.3 (c).
0.9‹
Where a wall is supported at each end by cross wall. OR,
Where a wall is supported at each end by pier/buttresses conforming to
Sec 7.4.3.3 (c).
1.0‹
Where a wall is free at one end and continuous with a cross wall at the
other end. OR,
Where a wall is free at one end and continuous with a pier/buttresses at
the other end conforming to Sec 7.4.3.3 (c).
1.5‹
Where a wall is free at one end and supported at the other end by a cross
wall. OR,
Where a wall is free at one end and supported at the other end by a
pier/buttresses conforming to Sec 7.4.3.3 (c).
2.0‹
7.4.2.5
Slenderness ratio
(a) Walls:  For a wall, slenderness ratio shall be the ratio of effective
height to effective thickness or effective length to effective thickness
whichever less is. In case of a load bearing wall, slenderness ratio
shall not exceed 20.
(b) Column:  For a column, slenderness ratio shall be taken to be the
greater of the ratio of effective heights to the respective effective
thickness in the two principal directions. Slenderness ratio for a load
bearing column shall not exceed 12.
7.4.2.6
Effective area
The effective cross-sectional area shall be based on the minimum bedded area of
the hollow units, or the gross area of solid units plus any grouted area. If hollow
units are used perpendicular to the direction of stress, the effective area shall be
lesser of the minimum bedded area or the minimum cross-sectional area. If bed
joints are raked, the effective area shall be correspondingly reduced. Effective
areas for cavity walls shall be that of the loaded wythes.

7.4.2.7
Flexural resistance of cavity walls
For computing the flexural resistance, lateral loads perpendicular to the plane of
the wall shall be distributed to the wythes according to their respective flexural
rigidities.
7.4.2.8
Effective width of intersecting walls
Where a shear wall is anchored to an intersecting wall or walls, the width of the
overhanging flange formed by the intersected walls on either side of the shear
wall shall not exceed 6 times the thickness of the intersected wall. Limits of the
effective flange may be waived if justified. Only the effective area of the wall
parallel to the shear forces may be assumed to carry horizontal shear.
7.4.3
Supports
7.4.3.1
Vertical support
Structural members providing vertical support of masonry shall provide a
bearing surface on which the initial bed joint shall not be less than 6 mm or
more than 25 mm and shall be of noncombustible materials, except where
masonry is a nonstructural decorative feature or wearing surface.

##### 7.4.3.2 Vertical deflection

Elements supporting masonry shall be designed so that their vertical deflection
does not exceed 1/600 of the clear span under total loads. Lintels shall be
supported on each end such that allowable stresses in the supporting masonry
are not exceeded. The minimum bearing length shall be 100 mm.
7.4.3.3
Lateral support
(a) Lateral support of masonry may be provided by cross walls, columns,
piers, counter forts or buttresses when spanning horizontally or by
floors, beams or roofs when spanning vertically.
(b) Lateral supports for a masonry element such as load bearing wall or
column shall be provided to
(i)
limit the slenderness of a masonry element so as to prevent or
reduce possibility of buckling of the member due to vertical
loads; and
(ii) resist the horizontal components of forces so as to ensure
stability of a structure against overturning.
(c) From consideration of slenderness (i.e. requirement b(i) above),
masonry elements may be considered to be laterally supported if
(i)
in case of a wall, where slenderness ratio is based on effective
height, floor/roof slab (or beams and slab) irrespective of the
direction of span, bears on the supported wall as well as cross
walls, to the extent of at least 100 mm;

(ii) in case of a wall, when slenderness ratio is based on its effective
length, a cross wall/pier/buttress of thickness equal to or more
than half the thickness of the supported wall or 125 mm,
whichever is more and average length equal to or more than
one-fifth of the height of the wall, is built at right angle to the
wall and properly bonded;
(iii) in case of a column, an RC or timber beam/RS joist/roof truss, is
supported on the column. In this case, the column will not be
considered to be laterally supported in the direction at right
angle to it; and
(iv) in case of a column, an RC beam forming a part of beam and slab
construction, is supported on the column, and the slab
adequately bears on stiffening walls. This construction will
provide lateral support to the column, in the direction of both
horizontal axes.
7.4.4
Stability
A wall or column subject to vertical and lateral loads may be considered to
provide adequate lateral support from consideration of stability, if the
construction providing the support is capable of resisting the following forces:
(a) Simple static reactions at the point of lateral support to all the lateral
loads; plus
(b) A lateral load equal to 2.5% of the total vertical load that the wall or
column is designated to carry at the point of lateral support.

##### 7.4.4.1 In case of load bearing buildings up to five storeys, stability

requirements may be considered to have been satisfied if the following
conditions are met.
(a) Height to width ratio of building does not exceed 2.
(b) Cross walls acting as stiffening walls continuous from outer wall to
outer wall or outer wall to a load bearing inner wall, and of thickness
and spacing as given in Table 6.7.9 are provided.
If stiffening wall or walls that are in a line, are interrupted by openings, length of
solid wall or walls in the zone of the wall that is to be stiffened shall be at least
one-fifth of the height of the opening.
(c) Floors and roof either bear on cross walls or are properly anchored
to those walls such that all lateral loads are safely transmitted to
those walls and through them to the foundation.
(d) Cross walls are built jointly with the bearing walls and jointly
mortared, or interconnected by toothing.
Cross walls may be anchored to walls to be supported by ties of noncorrosive
metal of minimum section 6 x 35 mm and length 60 mm with ends bent at least
50 mm, maximum vertical spacing of ties being 1.2 m.

Table 6.7.9: Thickness and Spacing of Stiffening Walls
Thickness of Load
Bearing Wall to be
Stiffened
(mm)
Height of
Storey not to
Exceed
(m)
Stiffening Wall \*
Thickness not less than
Maximum
spacing
(m)
1 to 3 storeys
(mm)
4 and 5 storeys
(mm)
above 300
3.2
3.2
3.4
5.0
---

4.5
6.0
8.0
8.0

* Storey height and maximum spacing as given are centre to centre dimensions.

##### 7.4.4.2 In case of walls exceeding 8 m in length, safety and adequacy of lateral

supports shall always be checked by structural analysis.

##### 7.4.4.3  A trussed roofing may not provide lateral support unless special

measures are adopted to brace and anchor the roofing. However, in case of
residential and similar buildings of conventional design with trussed roofing
having cross walls, it may be assumed that stability requirements are met  by
the cross walls and structural analysis for stability may be dispensed with.

##### 7.4.4.4 In case of walls exceeding 8 m in length, safety and adequacy of lateral

supports shall always be checked by structural analysis.

##### 7.4.4.5  A trussed roofing may not provide lateral support unless special

measures are adopted to brace and anchor the roofing. However, in case of
residential and similar buildings of conventional design with trussed roofing
having cross walls, it may be assumed that stability requirements are met  by
the cross walls and structural analysis for stability may be dispensed with.

##### 7.4.4.6 In case of external walls of basement and plinth, stability requirements

of Sec 7.4.4 may be considered to be satisfied if :
(a) Bricks used in basement and plinth have a minimum crushing
strength of 5 N/mm2 and mortar used in masonry is of Type M3 or
better,
(b) Clear height of ceiling in basement does not exceed 2.6 m,
(c) In the zone of action of soil pressure on basement walls, traffic load
excluding any surcharge due to adjoining buildings does not exceed
5 kN/m2,
(d) Minimum thickness of basement walls is in accordance with Table
6.7.10.
In case there is surcharge on basement walls from adjoining buildings, thickness
of basement walls shall be based on structural analysis.

| Thickness of Load<br />Bearing Wall to be<br />Stiffened<br />(mm) | Height of<br />Storey not to<br />Exceed<br />(m) | Stiffening Wall \*             | Col4                         | Col5                           |
| ------------------------------------------------------------------ | ------------------------------------------------- | ------------------------------ | ---------------------------- | ------------------------------ |
| Thickness of Load<br />Bearing Wall to be<br />Stiffened<br />(mm) | Height of<br />Storey not to<br />Exceed<br />(m) | Thickness not less than        | Thickness not less than      | Maximum<br />spacing<br />(m)  |
| Thickness of Load<br />Bearing Wall to be<br />Stiffened<br />(mm) | Height of<br />Storey not to<br />Exceed<br />(m) | 1 to 3 storeys<br />(mm)       | 4 and 5 storeys<br />(mm)    | 4 and 5 storeys<br />(mm)      |
| 100<br />200<br />300<br />above 300                               | 3.2<br />3.2<br />3.4<br />5.0                    | 100<br />100<br />100<br />100 | -<br />200<br />200<br />200 | 4.5<br />6.0<br />8.0<br />8.0 |

Table 6.7.10: Minimum Thickness of Basement Wall
Minimum Nominal
Thickness of Basement Wall
(mm)
Height of the Ground above Basement
Floor Level
Wall Loading (Permanent Load)
Less than 50 kN/m
More than 50 kN/m

### 2.0 m

### 1.4 m

### 2.5 m

### 1.8 m

7.4.4.7
Free standing  wall
Free standing walls, subject to wind pressure or seismic forces shall be designed
on the basis of permissible tensile stress in masonry or stability consideration.
However in Seismic Zones 1 and 2, free standing walls may be proportioned
without making any design calculations with the help of Table 6.7.11 provided
the mortar used is of type not leaner than M3. For parapet wall see Sec 7.4.9.4.
7.4.5
Structural Continuity
Intersecting structural elements intended to act as a unit shall be anchored
together to resist the design forces. Walls shall be anchored together to all
floors, roofs or other elements which provide lateral support for the wall. Where
floors or roofs are designed to transmit horizontal forces to walls, the
anchorages to the walls shall be designed to resist the horizontal forces.
Table 6.7.11: Height to Thickness Ratio of Free Standing Wall
Design Wind Pressure, N/m2
Height to Thickness Ratio
Up to 300
Note: Height is to be taken from 150 mm below ground level or top
of footing/ foundation block, whichever is higher, and up to the top
edge of the wall.

| Minimum Nominal<br />Thickness of Basement Wall<br />(mm) | Height of the Ground above Basement<br />Floor Level |
| --------------------------------------------------------- | ---------------------------------------------------- |
| Minimum Nominal<br />Thickness of Basement Wall<br />(mm) | Wall Loading (Permanent Load)                        |
| Minimum Nominal<br />Thickness of Basement Wall<br />(mm) | Less than 50 kN/m<br />More than 50 kN/m             |
| 375<br />250                                              | 2.0 m<br />1.4 m<br />2.5 m<br />1.8 m               |

7.4.5.1
Multi-wythe Walls
All wythes shall be bonded by grout or tied together by corrosion resistant wall
ties or joint reinforcement as follows:
(a) Wall Ties in Cavity Wall Construction: Wall ties shall be of sufficient
length to engage all wythes.  The portion of the wall ties within the
wythe shall be completely embedded in mortar or grout. The ends of
the wall ties shall be bent to 90 degree angles with an extension not
less than 50 mm long. Wall ties not completely embedded in mortar
or grout between wythes shall be a single piece with each end
engaged in each wythe.
There shall be at least one 6 mm diameter wall tie for each 0.45 m2 of
wall area. For cavity walls in which the width of the cavity is greater
than 75 mm, but not more than 115 mm, at least one 6 mm diameter
wall tie for each 0.3 m2 of wall area shall be provided.
Ties in alternate courses shall be staggered. The vertical distance
between ties shall not exceed 600 mm. The horizontal distance
between ties shall not exceed 900 mm. Additional ties spaced not
more than 900 mm apart shall be provided around and within 300
mm of the opening. Wall ties of different size and spacing may be
used if they provide equivalent strength between wythes.
(b) Wall Ties for Grouted Multi-wythe Construction: The two wythes
shall be bonded together with at least 6 mm diameter steel wall ties
for each 0.20 m2 of area. Wall ties of different size and spacing may be
used if they provide equivalent strength between wythes.
(c) Joint Reinforcement: Prefabricated joint reinforcement for masonry
walls shall have a minimum of one cross wire of at least 3 mm
diameter steel for each 0.2 m2 of wall area. The vertical spacing of the
joint reinforcement shall not exceed 400 mm. The longitudinal wires
shall be thoroughly embedded in the bed joint mortar. The joint
reinforcement shall engage all wythes.
Where the space between tied wythes is filled with grout or mortar,
the allowable stresses and other provisions for masonry bonded
walls shall apply. Where the space is not filled, tied walls shall
conform to the allowable stress, lateral support, thickness (excluding
cavity), height and tie requirements of cavity walls.

7.4.6
Joint Reinforcement and Protection of Ties
The minimum mortar cover between ties or joint reinforcement and any
exposed face shall be 15 mm. The thickness of grout or mortar between
masonry units and joint reinforcement shall not be less than 6 mm, except that
smaller diameter reinforcement or bolts may be placed in bed joints which are
at least twice as thick as the diameter of the reinforcement.
7.4.7
Pipes and Conduits
Pipe or conduit shall not be embedded in any masonry so as to reduce the
capacity to less than that necessary for required stability or required fire
protection, except the following:
(a) Rigid electrical conduit may be embedded in structural masonry
when their location has been detailed on the approved plan.
(b) Any pipe or conduit may pass vertically or horizontally through any
masonry by means of a sleeve at least large enough to pass any hub
or coupling on the pipeline. Such sleeves shall not be placed closer
than three diameters, centre to centre, nor shall they unduly impair
the strength of construction.
(c) Placement of pipes or conduits in unfilled cores of hollow unit
masonry shall not be considered as embedment.
7.4.8
Loads and Load Combination

##### 7.4.8.1 Design loads

All design loads and other forces to be taken for the design of masonry
structures shall conform to Chapter 2, Loads.
7.4.8.2
Load dispersion
The angle of dispersion of vertical load on walls shall be taken as not more than
30o from the vertical.
7.4.8.3
Distribution of concentrated vertical loads in walls
The length of wall, laid up in running bond, which may be considered capable of
working at the maximum allowable compressive stresses to resist vertical
concentrated loads, shall not exceed the centre to centre distance between such
loads, nor the width of bearing area plus four times the wall thickness.
Concentrated vertical loads shall not be assumed distributed across continuous
vertical mortar or control joints unless elements designed to distribute the
concentrated vertical loads are employed.

7.4.8.4
Loads on non-bearing wall
Masonry walls used as interior partition or as exterior surfaces of building
which do not carry vertical loads imposed by other elements of the building
shall be designed to carry their own weight plus any superimposed finish and
lateral forces. Bonding or anchorage of nonbearing walls shall be adequate to
support the walls and to transfer lateral forces to the supporting structures.
7.4.8.5
Load combinations
Load combination for design of masonry structures shall conform to
requirements of Sec 2.7 Chapter 2 Part 6.
7.4.9
Minimum Design Dimensions
7.4.9.1
Minimum thickness of load bearing walls
The nominal thickness of masonry bearing walls in building shall not be less
than 250 mm.
Exception:
Stiffened solid masonry bearing walls in one-storey buildings may have a
minimum effective thickness of 165 mm when not over 3 m in height, provided
that when gable construction is used an additional 1.5 m height may be
permitted at the peak of the gable.
7.4.9.2
Variation in thickness
When a change in thickness due to minimum thickness requirements occurs
between floor levels, the greater thickness shall be carried up to the higher floor
level.
7.4.9.3
Decrease in thickness
When walls of masonry of hollow units or masonry bonded hollow walls are
decreased in thickness, a course or courses of solid masonry shall be
constructed between the walls below and the thinner wall above, or special
units or construction shall be used to transmit the loads from wythes to the
walls below.
7.4.9.4
Parapet wall
Parapet walls shall be at least 200 mm thick and height shall not exceed 4 times
the thickness. The parapet wall shall not be thinner than the wall below.

7.5
Design of Unreinforced Masonry
7.5.1
General
The requirements of this Section are applicable to unreinforced masonry in
addition to the requirements of Sec 7.4.
7.5.2
Design of Members Subjected to Axial Compression
The stresses due to compressive forces applied at the centroid of any load
bearing wall, column and pilaster may be computed by Eq. 6.7.22 below
assuming uniform distribution over the effective area.

e
a
A
P
f 

(6.7.22)
7.5.3
Design of Members Subjected to Combined Bending and Axial
Compression
(a) Compressive stresses due to combined bending and axial load shall satisfy
the requirements of Sec 7.3.5.
(b) Resultant tensile stress due to combined bending and axial load shall not
exceed the allowable flexural tensile stress, ƒ as specified in Sec 7.3.
7.5.4
Design of Members Subjected to Flexure
Stresses due to flexure calculated by Eq. 6.7.23 below shall not exceed the values
given in Sec 7.3.5.
I
Mc
fb 

(6.7.23)
7.5.5
Design of Members Subjected to Shear
Shear calculations in flexural members and shear walls shall be based on Eq.

#### 6.7.24 below.

M =
s
ßì

(6.7.24)
7.5.6
Design of Arches
Geometrical form and the cross-sectional dimensions of masonry arch shall be
selected such that the line of thrust at any section of the arch is kept within the
middle third of the section of the arch rib. The elastic theory of arches shall be
permitted for the analysis of unreinforced masonry arches. All supports of
arches shall be capable of developing the required horizontal thrust without
suffering unacceptable displacements. Every arch must be designed to resist the
stresses due to the following loads:

(a) Gravity loads :
(i)
Dead loads shall be placed in conformity with their actual
distribution.
(ii) Live loads shall be positioned to cover entire span or part of the
span as necessary to produce the maximum stresses at the
crown, springing and all other sections of the arch rib.
(b) Loads due to temperature change.
(c) Shrinkage load due to setting and hardening.
(d) Shortening of arch rib under thrust caused by loads.
7.5.7
Footings and Corbels
The slope of footing and corbelling (measured from the horizontal to the face of
the corbelled surface) shall not be less than 60 degrees.
The maximum horizontal projection of corbelling from the plane of the wall
shall be such that stress at any section does not exceed the allowable value.
7.6
Design of Reinforced Masonry
7.6.1
General
The requirements of this Section are in addition to those specified in Sec 7.4 and
are applicable to reinforced masonry. Plain bars larger than 6 mm in diameter
shall not be used.
7.6.1.1
Assumptions
The following assumptions shall be applicable for this Section.
(a) Masonry carries no tensile stress.
(b) Reinforcement is completely surrounded by and bonded to masonry
material so that they work together as a homogeneous material
within the range of working stresses.
7.6.2
Design of Members Subjected to Axial Compression
Stresses due to compressive forces applied at the centroid of load bearing wall,
column and pilaster may be computed assuming uniform distribution over the
effective area. Stress shall be calculated from Eq. 6.7.25 below:
e
a
A
p
f


(6.7.25)

7.6.3
Design of Members Subjected to Combined Bending and Axial
Compression
Stress due to combined bending and axial loads shall satisfy the requirements of
Sec 7.3.5. Columns and walls subjected to bending with or without axial loads
shall meet all applicable requirements for flexural design.

The design of walls with an (h//t) ratio larger than 30 shall be based on forces
and moments determined from analysis of structure. Such analysis shall take
into account influence of axial loads and variable moment of inertia on member
stiffness and fixed end moments, effect of deflections on moments and forces,
and the effects of duration of loads.
7.6.4
Design of Members Subjected to Shear  Force
Shearing stresses in flexural members and shear walls shall be computed by
bjd
V
νf 

(6.7.26)

When the computed shear stress exceeds the allowable value, web
reinforcement shall be provided and designed to carry the total shear force.
Both vertical and horizontal shear stresses shall be considered. The area
required for shear reinforcement placed perpendicular to the longitudinal
reinforcement shall be computed by Eq. 6.7.27 below:
d
F
sV
A
s
ν 

(6.7.27)

Spacing of vertical shear reinforcement shall not exceed d/2, nor 600 mm.
Inclined shear reinforcement shall have a maximum spacing of 0.3750(1 +
\$›u), but not greater than 600 mm, where α is the acute angle between inclined
bar and the horizontal.
7.6.5
Design of Members Subjected to Flexural Stress
7.6.5.1
Rectangular elements
Rectangular flexural elements shall be designed in accordance with the
following equations or other methods based on the simplified assumptions.
(a) Compressive stress in the masonry:







jk
f
b
bd
M

(6.7.28)

(b) Tensile stress in the longitudinal reinforcement:
d
f
j
A
M
s
s 

(6.7.29)

(c) Design coefficients :

* \= \[(ঙ্চ্)য় + ২ঙ্চ্]/য় −ঙ্চ্
  (6.7.30)

Or,

* \=

' Î&
ËÎ

(6.7.31)

/ = 1 −
(
½
(6.7.32)
7.6.5.2
Nonrectangular sections
Flexural elements of nonrectangular cross-section shall be designed in
accordance with the assumptions given in Sec 7.4.2.1 and 7.6.1.1.
7.6.5.3
Lateral support
The clear distance between lateral supports of a beam shall not exceed 32 times
the least depth of compression area.
7.6.5.4
Effective width
In computing flexural stresses in walls where reinforcement occurs, the
effective width assumed for running bond masonry shall not exceed 6 times the
nominal wall thickness or the centre to centre distance between reinforcement.
Where stack bond is used, the effective width shall not exceed 3 times the
nominal wall thickness or the centre to centre distance between reinforcement
or the length of one unit, unless grouted solid using open-ended joints.
7.6.5.5
Bond
In flexural members in which tensile reinforcement is parallel to the
compressive face, the bond stress shall be computed by the formula:
d
u
j
V
o



(6.7.33)
7.6.6
Reinforcement Requirements and Details
7.6.6.1
Column reinforcement
(a) Vertical Reinforcement: The area of vertical reinforcement shall not
be less than 0.005 Ae and not more than 0.04Ae. At least four 10 mm
bars shall be provided.

(b) Lateral Ties: All longitudinal bars for columns shall be enclosed by
lateral ties. Lateral support shall be provided to the longitudinal bars
by the corner of a complete tie having an included angle of not more
than 135 degrees or by a hook at the end of a tie. The corner bars
shall have such support provided by a complete tie enclosing the
longitudinal bars. Alternate longitudinal bars shall have such lateral
support provided by ties and no bar shall be farther than 150 mm
from such a laterally supported bar.
Lateral ties and longitudinal bars shall be placed not less than 40 mm
and not more than 125 mm, from the surface of the column. Lateral
ties may be against the longitudinal bars or placed in the horizontal
bed joint if the requirements of Sec 4.4.6 are met. Spacing of ties shall
not be more than 16 times longitudinal bar diameter, 48 times tie bar
diameter or the least dimension of the column but not more than 450
mm.
Ties shall be at least 6 mm in diameter for 22 mm diameter or
smaller longitudinal bars and 10 mm in diameter for larger
longitudinal bars. Ties less than 10 mm in diameter may be used for
longitudinal bars larger than 22 mm in diameter, provided the total
cross-sectional area of such smaller ties crossing a longitudinal plane
is equal to that of the larger ties at their required spacing.
(c) Anchor Bolt Ties: Additional ties shall be provided around anchor
bolts which are set in the top of the column. Such ties shall engage at
least four bolts or, alternatively at least four vertical column bars or a
combination of bolts and bars totaling four in number. Such ties shall
be located within the top 125 mm of the column and shall provide a
total of 250 square millimeters or more in cross-sectional area. The
upper most ties shall be within 50 mm of the top of the column.
7.6.6.2
Maximum reinforcement size
The maximum size of reinforcing bars shall be 35 mm. Maximum steel area in
cell shall be 6 percent of the cell area without splices and 12 percent of cell area
with splices.
7.6.6.3
Spacing of longitudinal reinforcement
The clear distance between parallel bars, except in columns, shall not be less
than the nominal diameter of the bars or 25 mm, except that bars in a splice may
be in contact. This clear distance requirement applies to the clear distance
between a contact splice and adjacent splices or bars. The minimum clear
distance between parallel bars in columns shall be two and one-half times the
bar diameter.

The clear distance between the surface of a bar and any surface of a masonry
unit shall not be less than 6 mm for fine grout and 12 mm for coarse grout. Cross
webs of hollow units may be used as support for horizontal reinforcement.
All reinforcing bars, except joint reinforcing, shall be completely embedded in
mortar or grout and have a minimum cover, including the masonry unit, as
specified below:
(a) 20 mm when not exposed to weather
(b) 40 mm when exposed to weather
(c) 50 mm when exposed to soil
7.6.6.4
Anchorage of Flexural Reinforcement
(a)  The tension or compression in any bar at any section must be
developed on each side of that section by the required development
length. The development length of the bar may be achieved by a
combination of an embedment length, anchorage or, for tension only,
hooks.
The required development length for deformed bars or deformed
wires shall be calculated by:
For bar in tension,
িে = ০.২৯০১
(6.7.34)
For bar in compression,
িে = ০.২২০১
(6.7.35)
Development length for plain bars shall be 2.0 times the length
calculated by Eq. 6.7.34.

(b) Except at supports, or at the free end of cantilevers, every reinforcing
bar shall be extended beyond the point at which it is no longer
needed to resist tensile stress for a distance equal to 12 bar
diameters or the depth of the flexural member, whichever is greater.
No flexural bars shall be terminated in a tensile zone unless one of
the following conditions is satisfied:
(i)
The shear is not over one-half of that permitted, including
allowance for shear reinforcement, if any.
(ii) Additional shear reinforcement in excess of that required is
provided each way from the cutoff a distance equal to the depth
of the beam. The shear reinforcement spacing shall not exceed
d/8rb, where rb is the ratio of the area of bars cutoff to the total
area of bars at the section.
(iii) The continuing bars provide double the area required for
flexure at that point or double the perimeter required for
reinforcing bond.

(c) At least one third of the total reinforcement provided for negative
moment at the support shall be extended beyond the extreme
position of the point of inflection a distance sufficient to develop one
half the allowable stress in the bar, one sixteenth of the clear span, or
the depth d of the member, whichever is greater.
(d) Tensile reinforcement of negative moment in any span of a
continuous restrained or cantilever beam, or in any member of a rigid
frame, shall be adequately anchored by reinforcing bond, hooks or
mechanical anchors in or through the supporting member.
(e) At least one third of the required positive moment reinforcement in
simple beams or at the freely supported end of continuous beams
shall extend along the same face of the beam into the support at least
150 mm. At least one fourth of the required positive moment
reinforcement at the continuous end of continuous beams shall
extend along the same face of the beam into the support at least 150
mm.
(f)
Compression reinforcement in flexural members shall be anchored
by ties or stirrups not less than 6 mm in diameter, spaced not farther
apart than 16 bar diameters or 48 tie diameters whichever is smaller.
Such ties or stirrups shall be used throughout the distance where
compression steel is required.
(g) In regions of moment where the design tensile stresses in the steel
are greater than 80 percent of the allowable steel tensile stress (Fs),
the lap length of splices shall be increased not less than 50 percent of
the minimum required length. Other equivalent means of stress
transfer to accomplish the same 50 percent increase may be used.
7.6.6.5
Anchorage of shear reinforcement
(a) Single separate bars used as shear reinforcement shall be anchored at
each end by one of the following methods:
(i)
Hooking tightly around the longitudinal reinforcement through
180 degrees.
(ii) Embedment above or below the mid-depth of the beam on the
compression side a distance sufficient to develop the stress in
the bar for plane or deformed bars.
(iii) By  a standard hook (see Sec 7.6.6.6) considered as developing
50 N/mm2, plus embedment sufficient to develop the remainder
of the stress to which the bars are subject. The effective
embedded length shall not be assumed to exceed the distance
between the mid-depth of the beam and the tangent of the hook.

(b) The ends of bars forming single U or multiple U stirrups shall be
anchored by one of the methods specified above or shall be bent
through an angle of at least  90 degrees tightly around a longitudinal
reinforcing bar not less in diameter than the stirrup bar, and shall
project beyond the bend at least 12 diameters of the stirrup.
(c) The loops or closed ends of single U or multiple U stirrups shall be
anchored by bending around the longitudinal reinforcement through
an angle of at least 90 degrees and project beyond the end of the
bend at least 12 diameters of the stirrup.
7.6.6.6
Hooks
(a) The term "standard hook" shall mean one of the following:
(i)
A 180 degree turn plus an extension of at least 4 bar diameters
but not less than 65 mm at the free end of the bar.
(ii) 90 degree turn plus an extension of at least 12 bar diameters at
the free end of the bar.
(iii) For stirrup and tie anchorage only either a 90 degree or a 135
degree turn, plus an extension of at least 6 bar diameters but
not less than 65 mm at the free end of the bar.
(b) The diameter of bend measured on the inside of the bar other than
stirrups and ties, shall not be less than that set forth in Table 6.7.12.
Table 6.7.12: Minimum Diameter of Bend
Bar Diameter
Minimum Diameter of Bend
6 to 25 mm
6 bar diameters
8 to 35 mm
8 bar diameters
(c) Inside diameter of bend for 12 mm diameter or smaller stirrups and
ties shall not be less than 4 bar diameters. Inside diameter of bend for
16 mm diameter or larger stirrups and ties shall not be less than that
given in Table 6.7.12.
(d) Hooks shall not be permitted in the tension portion of any beam,
except at the ends of simple or cantilever beams or at the freely
supported ends of continuous or restrained beams.
(e) Hooks shall not be assumed to carry a load which would produce a
tensile stress in the bar greater than 50 N/mm2.

(f)
Hooks shall not be considered effective in adding to the compressive
resistance of bars.
(g) Any mechanical device capable of developing the strength of the bar
without damage to the masonry may be used in lieu of a hook. Data
must be presented to show the adequacy of such devices.
7.6.6.7
Splices
The amount of lap of lapped splices shall be sufficient to transfer the allowable
stress of the reinforcement as in Sec 7.6.6.4. In no case shall the length of the
lapped splice be less than 30 bar diameters for compression and 40 bar
diameters for tension.
Welded or mechanical connections shall develop 125 percent of the specified
yield strength of the bar in tension, except for connections of compression bars
in columns that are not part of the seismic system and are not subject to flexure,
where the compressive strength only need be developed.
When adjacent splices in grouted masonry are separated by 75 mm or less, the
lap length shall be increased by 30 percent or the splice may be staggered at
least 24 bar diameters with no increase in lap length.
7.7
Strength Design of Slender Walls and Shear Walls
7.7.1
Design of Slender Walls
In lieu of the procedure set forth in Sec 7.6, the procedures prescribed in this
Section, which consider the slenderness of walls by representing effects of axial
forces and deflection in calculation of moments, may be used when the vertical
load stress at the location of maximum moment computed by Eq. 6.7.36 does
not exceed 0.04fr . The value of fr shall not exceed 40 N/mm2.
ªâ'ªÎ
ßÁ
≤0.04fr
(6.7.36)
Slender masonry walls shall have a minimum nominal thickness of 150 mm.
7.7.1.1
Slender wall design procedure
(a) Maximum Reinforcement: The reinforcement ratio shall not exceed
0.5b, where b is the balanced steel ratio.
(b) Moment and Deflection Calculation: All moments and deflections of
slender walls shall be calculated based on simple support conditions
at top and bottom. For other support and fixity conditions, moments
and deflections shall be calculated using established principles of
mechanics.

7.7.1.2
Strength design
(a) Loads: Factored loads shall be determined in accordance with
Chapter 2, Loads.
(b) Required Moment: Required moment and axial force shall be
determined at the mid-height of the wall and shall be used for design.
The factored moment, Mu, at the mid-height of the wall shall be
determined by Eq. 6.7.37.
pk =
^àZë
Í

* Žk
  !
  q + ÕŽk^ + Žk\`Ù∆k
  (6.7.37)
  Where,

∆k =  horizontal deflection at mid-height under factored load; P -
Delta effects shall be included in deflection calculation.
•  = eccentricity of Pu

Žk =  axial load at mid-height of wall, including tributary wall
weight.

\= Žk^ + Žk\`
(c) Design Strength: Design strength in flexure is the nominal moment strength,
ph multiplied by the strength reduction factor, •  and shall equal or exceed
the factored moment, pk
pk ≤•ph
(6.7.38)
Where,
ph = nominal moment strength

\= -!(0 −2/2)
-! = effective area of steel

\=
ß&`Ï'ªà
`Ï
and
\= depth of stress block due to factored loads.

\=
ß&`Ï'ªà
².Í`×Å 1

The strength reduction factor • for flexure shall be 0.80.

(d)  Design Assumptions: The following are the design assumptions for
calculation of nominal strength.
(i)
Nominal strength of singly reinforced masonry wall cross-
sections subject to combined flexure and axial load shall be
based on applicable conditions of equilibrium and compatibility
of strains.
(ii) Strain in reinforcement and masonry walls shall be assumed
directly proportional to the distance from the neutral axis.
(iii) Maximum usable strain at extreme masonry compression fibre
shall be assumed equal to 0.003.
(iv) Stress in reinforcement below specified yield strength  shall
be taken as  times steel strain. For strains greater than that
corresponding to  stress in reinforcement shall be considered
independent of strain and equal to.
(v) Tensile strength of masonry walls shall be neglected in flexural
calculations of strength, except for deflection calculation.
(vi) Relationship between masonry compressive stress and masonry
strain may be assumed to be rectangular as defined by the
following:

Masonry stress of 0.85fr shall be assumed uniformly
distributed over an equivalent compression zone bounded by
edges of the cross-section and a straight line located parallel to
the neutral axis at a distance a = 0.85c from the fibre of
maximum compressive strain.

Distance c from fibre of maximum strain to the neutral axis shall
be measured in a direction perpendicular to that axis.
7.7.1.3
Deflection calculation
The mid-height deflection, ∆ under service lateral and vertical loads (without
load factors) shall be limited to:
∆= 0.007ℎ
(6.7.39)
The mid-height deflection shall be computed by:
When, p! ≤p
∆=
¹\&Zë
îÍ"×ÀÁ
(6.7.40)
When, p « p! « ph
∆=
¹±ºZë
îÍ"×ÀÁ + 5
(¹&ìºØ¹±º)Zë
îÍ"×À±º

(6.7.41)

The cracking moment strength of the wall p  shall be determined by:
p = .
(6.7.42)
The modulus of rupture,  shall be determined form Table 6.7.13.
Table 6.7.13: Values of the Modulus of Rupture, 

Type of Masonry
Fully Grouted
Partially Grouted
Solid Masonry
0.17fr ≤0.65 N/mmq
Not allowed
Hollow Unit Masonry
0.33fr ≤1.2 N/mmq
0.21fr ≤0.65 N/mmq
7.7.2
Design of Shear Walls
Based on ultimate strength design, the procedures described below may be used
as an alternative to the procedure specified in Sec 7.6 for the design of
reinforced hollow unit masonry shear walls. Provisions for quality control
during construction of the shear wall are specified in Sec 7.3.4
7.7.2.1
Required strength
The required strength to resist different combinations of loads shall be
determined in accordance with Sec 2.7.3.1 Chapter 2 of this Part.
7.7.2.2
Design strength
Shear walls shall be proportioned such that the design strength exceeds the
required strength. Design strength in terms of axial force, shear force and
moment provided by the shear wall shall be computed as the nominal strength
multiplied by the strength reduction factor •.
Strength reduction factor •
shall be as follows:
(a) For axial load and axial load with flexure • = 0.65
(b) For members with  less than 410 N/mm2 and with symmetrical
reinforcement, • may be increased linearly to 0.85 as •Žh  decreases
from 0.10fr -! or 0.25Ž1 to zero.
For solid grouted walls Ž1 may be calculated using:
Ž1 = 0.85fr y21
(6.7.43a)

Where,

2y = 0.85 •>¬/ ¸•>¬ +  /
¼ 0
(6.7.43b)

(c) For shear • = 0.60. The shear strength reduction factor may be
increased to 0.80 for any shear wall when its nominal shear strength
exceeds the shear corresponding to development of its nominal flexural
strength for the factored load combination.
7.7.2.3
Design Assumptions for Nominal Strength
(a) Nominal strength of shear wall cross-sections shall be based on
assumptions specified in Sec 7.7.1.2(d).
(b) The maximum usable strain •fk, at the extreme masonry
compression fibre shall not exceed 0.003.
(c) fr shall not be less than 7 N/mm2  or greater than 20 N/mm2.
7.7.2.4
Axial Strength
The nominal axial strength of shear walls supporting axial loads only shall be
calculated by Eq 6.7.44.
Žo = 0.85fr (-! −-) + -
(6.7.44)
The shear wall shall be designed for the axial strength Pu, such that
Žk ≤∅(0.80)Ž²
(6.7.45)
7.7.2.5
Shear strength
(a) The nominal shear strength shall be determined by the provisions as
specified in (b) or (c) below. The maximum nominal shear strength
values are given in Table 6.7.14.
Table 6.7.14: Maximum Nominal Shear Strength Values
@∗
ô
ô
81
r
≤ 0.25
≥1.00
72.0
48.0

* M is the maximum bending moment that occurs simultaneously with the shear
  load V at the section under consideration. Interpolation may be by straight line
  for M/Vd values between 0.25 and 1.00.

(b) The nominal shear strength of shear walls except for shear walls
specified in (c) below shall be determined by Eq. 6.7.46.
্থয = ্থভ + ্থ
(6.7.46)
Where,
্থভ = ০.০৮৩-িভগভৎ
(6.7.47)
The value of Cd in Eq. 6.7.47 is given as:
w = 2.4  for
¹
sw ≤0.25
(6.7.48a)
w = 1.2  for
¹
sw ≥1.0
(6.7.48b)
্থ = -ভগ
h
(6.7.48c)
(c) For a shear wall whose nominal shear strength exceeds the shear
corresponding to development of its nominal flexural strength, two
shear regions exist.
(i)
For all cross-sections within the region defined by the base of
the shear wall and a plane at a distance ‹^ above the base of the
shear wall, the nominal shear strength shall be determined by
Eq. 6.7.49
্থঙ্ = ->ঙ্
•
(6.7.49)
The required shear strength for this region shall be calculated at a
distance
্তব্জ
q above the base of the shear wall but not to exceed one-
half storey height.
(ii) For the other region, the nominal shear strength of the shear
wall shall be determined by Eq. 6.7.46.
7.7.2.6
Reinforcement
Reinforcement shall be in accordance with the following:
(a) Minimum reinforcement shall be provided in accordance with Sec

##### 7.8.5.1 for all seismic areas using this method of analysis.

(b) When the shear wall failure mode is in flexure, the nominal flexural
strength of the shear wall shall be at least 1.8 times the cracking
moment strength of a fully grouted wall or 3.0 times the cracking
moment strength of a partially grouted wall as obtained from Eq.
6.7.42.
(c) All continuous reinforcement shall be anchored or spliced in
accordance with Sec 7.6.6.4 with  = 0.5.

(d) Vertical reinforcement shall not be less than 50 percent of the
horizontal reinforcement.
(e) Spacing of horizontal reinforcement within the region defined in Sec
7.7.2.5(c) shall not exceed three times the nominal wall thickness or
600 mm, whichever is smaller.
7.7.2.7
Boundary  member
Boundary members shall be as follows:
(a) The need for boundary members at boundaries of shear wall shall be
determined using the provisions set forth in (b) or (c) below.
(b) Boundary members shall be provided when the failure mode is flexure
and the maximum extreme fibre stress exceeds  0.2fr . The boundary
members may be discontinued where the calculated compressive stresses
are less than  0.15fr . Stresses may be calculated for the factored forces
using a linearly elastic model and gross section properties.
(c) When the failure mode is flexure, boundary member shall be provided to
confine all vertical reinforcement whose corresponding masonry
compressive stress exceeds  0.4fr . The minimum length of the boundary
member shall be 3 times the thickness of the wall.
(d) Boundary members shall be confined with minimum of 10 mm diameter
bars at a maximum of 200 mm spacing or equivalent within the grouted
core and within the region defined by the base of the shear wall and a
plane at a distance ‹^ above the base of the shear wall.
7.8
Earthquake Resistant Design
7.8.1
General
All masonry structures constructed in the Seismic Zones 2, 3 and 4 shown in
Figure 6.2.13 shall be designed in accordance with the provisions of this Section.
7.8.2
Loads
Seismic forces on masonry structures shall be determined in accordance with
the provisions of Sec 2.5 Chapter 2 of this Part.
7.8.3
Materials
(a) Well burnt clay bricks and concrete hollow blocks having a crushing
strength not less than 12 N/mm2 shall be used.
(b) Mortar not leaner than p½ shall be used for masonry constructions.

7.8.4
Provisions  for Seismic Zone 2 and 3
7.8.4.1
Wall Reinforcement
Vertical reinforcement of at least 12 mm diameter shall be provided
continuously from support to support at each corner, at each side of each
opening, at the ends of walls and at a maximum spacing of 1.2 m horizontally
throughout the wall. Horizontal reinforcement not less than 12 mm diameter
shall be provided:
(a) at the bottom and top of wall openings and shall extend at least 40
bar diameters, with a minimum of 600 mm,  past the opening,
(b) continuously at structurally connected roof and floor levels and at the
top of walls,
(c) at the bottom of the wall or in the top of the foundations when
dowelled to the wall,
(d) at maximum spacing of 3.0 m unless uniformly distributed joint
reinforcement is provided. Reinforcement at the top and bottom of
openings when continuous in the wall may be used in determining
the maximum spacing specified in item (a) above.
7.8.4.2
Stack bond
Where stack bond is used, the minimum horizontal reinforcement ratio shall be
0.0007y›. This ratio shall be satisfied by uniformly distributed joint
reinforcement or by horizontal reinforcement spaced not more than 1.2 m and
fully embedded in grout or mortar.
7.8.4.3
Columns
Columns shall be reinforced as specified in Sec 7.6.6.1.
7.8.5
Provisions for Seismic Zone 4
All masonry structures built in Seismic Zone 4 shall be designed and constructed
in accordance with requirements for Seismic Zone 2 and with the following
additional requirements and limitations.

Reinforced hollow unit stack bond construction which is part of the seismic
resisting system shall use open-end units so that all head joints are made solid,
shall use bond beam units to facilitate the flow of grout and shall be grouted
solid.
7.8.5.1
Wall reinforcement
Reinforced masonry walls shall be reinforced with both vertical and horizontal
reinforcement. The sum of the areas of horizontal and vertical reinforcement
shall be at least 0.002 times the gross cross-sectional area of the wall and the
area of reinforcement in either direction shall not be less than 0.0007 times the
gross cross-sectional area of the wall. The spacing of reinforcement shall not

exceed 1.20 m. The diameter of reinforcing bar shall not be less than 10 mm
except that joint reinforcement may be considered as part of all of the
requirements for minimum reinforcement. Reinforcement shall be continuous
around wall corners and through intersections. Only reinforcement which is
continuous in the wall or element shall be considered in computing the
minimum area of reinforcement. Reinforcement with splices conforming to Sec

##### 7.6.6.7 shall be considered as continuous reinforcement.

7.8.5.2
Column reinforcement
The spacing of column ties shall be not more than 225 mm for the full height of
columns stressed by tensile or compressive axial overturning forces due to the
seismic loads, and 225 mm for the tops and bottoms of all other columns for a
distance of one sixth of the clear column height, but not less than 450 mm or
maximum column dimension. Tie spacing for the remaining column height shall
be not more than 16 bar diameters, 48 tie diameters or the least column
dimension, but not more than 450 mm.
7.8.5.3
Stack bond
Where stack bond is used, the minimum horizontal reinforcement ratio shall
be 0.0015y›. If open-end units are used and grouted solid, the minimum
horizontal reinforcement ratio shall be 0.0007y›.
7.8.5.4
Minimum dimension
(a) Bearing Walls: The nominal thickness of reinforced masonry bearing
walls shall be not less than 150 mm except that nominal 100 mm
thick load bearing reinforced hollow clay unit masonry walls may be
used, provided net area unit strength exceeds 55 N/mm2, units are
laid in running bond, bar sizes do not exceed 12 mm with no more
than two bars or one splice in a cell, and joints are flush cut, concave
or a protruding V section.
(b) Columns:  The least nominal dimension of a reinforced masonry
column shall be 375 mm except that if the allowable stresses are
reduced to 50 percent of the values given in Sec 7.3, the minimum
nominal dimension shall be 250 mm.
7.8.5.5
Shear wall
(a) When calculating shear or diagonal tension stresses, shear walls
which resist seismic forces shall be designed to resist 1.5 times the
forces specified in Chapter 2, Loads.
(b) The portion of the reinforcement required to resist shear shall be
uniformly distributed and shall be joint reinforcing, deformed bars,
or a combination thereof. The maximum spacing of reinforcement in
each direction shall be not less than the smaller of one-half the length
or height of the element or more than 1.20 m.

Joint reinforcement used in exterior walls and considered in the
determination of the shear strength of the member shall conform to
the requirement "Joint Reinforcement for Masonry" (UBC Standard
No. 24-15) or "Standard Specification for Steel Wire, Plain, for
Concrete Reinforcement", (ASTM, A82).
Reinforcement required to resist in-plane shear shall be terminated
with a standard hook or with an extension of proper embedment
length beyond the reinforcing at the end of the wall section. The hook
or extension may be turned up, down or horizontally. Provisions shall
be made not to obstruct grout placement. Wall reinforcement
terminating in columns or beams shall be fully anchored into these
elements.
(c) Multi-wythe grouted masonry shear walls shall be designed with
consideration of the adhesion bond strength between the grout and
masonry units. When bond strengths are not known from previous
tests, the bond strength shall be determined by test.
7.8.5.6
Hook
The standard hook for tie anchorage shall have a minimum turn of 135 degrees
plus an extension of at least 6 bar diameters, but not less than 100 mm at the
free end of the bar.  Where the ties are placed in the horizontal bed joints, the
hook shall consist of a 90 degree bend having a radius of not less than 4 tie
diameters plus an extension of 32 tie diameters.
7.8.5.7
Mortar joints between masonry and concrete
Concrete abutting structural  masonry such as at starter courses or at wall
intersections not designed as true separation joints shall be roughened to a full
amplitude of\` 1.5 mm and shall be bonded to the masonry as per the
requirements of this Section as if it were masonry.
7.8.6
Additional Requirements
7.8.6.1
Opening in bearing walls
(a) Tops of all openings in a storey shall preferably be at the same level
so that a continuous band could be provided over them, including the
lintels throughout the building.
(b) The total width of the openings shall not be more than half of the
length of the walls between the adjacent cross walls, except as
provided  in (f) below.
(c) The opening shall preferably be located away from the corner by a
clear distance of at least one-eighth of the height of the opening for
Seismic Zones 2 and 3, and one-fourth of the height for Seismic Zone 4.

(d) The horizontal distance between two openings shall not be less than
one-fourth of the height of the shorter opening for Seismic Zones 2
and 3, and one-half of the height for Seismic Zone 4.
(e) The vertical distance between openings one above the other shall be
not less than 600 mm.
(f)
Where openings do not comply with the requirements of (b) and (c)
above, they shall be strengthened in accordance with Sec 7.8.6.5.
(g) If a window or ventilator is to be projected out, the projection shall
be in reinforced masonry or concrete and well anchored.
(h) If the height of an opening is approximately full height of a wall,
dividing the wall into two portions, these portions of the wall shall be
reinforced with horizontal reinforcement of 6 mm diameter bars at
not more than 600 mm intervals, one on inner and one on outer face,
properly tied to vertical steel at jambs and corners or junctions of
walls where used.
(i)
The use of arches to span over the openings is a source of
weakness and shall be avoided unless steel ties are provided.
7.8.6.2
Strengthening arrangements
All masonry buildings shall be strengthened by the methods specified in Table
6.7.15.
Table 6.7.15: Strengthening of Masonry Buildings for Earthquake
Seismic
Zones
No. of
Storey
Strengthening Arrangements to be Provided.
Up to 4
a) Masonry mortar shall not be leaner than p½
2, 3
Up to 2
with
pitched
roof
a) Masonry mortar shall not be leaner than p½
b) By lintel and roof band (Sec 7.8.6.3)
c)  By vertical reinforcement at corners and junctions of
walls (Sec 7.8.6.4)
d) Bracing in plan at tie level for pitched roof\*
3 to 4
a) Masonry mortar shall not be leaner than p½
b) By lintel and roof band (Sec 7.8.6.3)
c) By vertical reinforcement at corners and junctions of
walls (Sec 7.8.6.4)
d) Vertical
reinforcement
at
jambs
of
openings
(Sec 7.8.6.5)
e) Bracing in plan at tie level for pitched roof\*

Seismic
Zones
No. of
Storey
Strengthening Arrangements to be Provided.
Up to 4

a) Masonry mortar shall not be leaner than p½
b) By lintel and roof band (Sec 7.8.6.3)
c)  By vertical reinforcement at corners and  junctions of
walls (Sec 7.8.6.4)
d) Vertical
reinforcement
at
jambs
of
openings
(Sec 7.8.6.5)
e) Bracing in plan at tie level for pitched roof\*
 At tie level all the trusses and the gable end shall be provided with diagonal
bracing in plan so as to transmit the lateral shear due to earthquake force to
the gable walls acting as shear walls at the ends.
7.8.6.3
Bands
Roof band need not be provided underneath reinforced concrete or brickwork
slabs resting on bearing walls, provided that the slabs are continuous over parts
between crumple sections, if any, and cover the width of end walls fully.
The band shall be made of reinforced concrete with r
not less than 20 N/mm2
or reinforced brickwork in cement mortar not leaner than 1: 4. The bands shall
be to the full width of the wall and not less than 75 mm in depth and shall be
reinforced as indicated in Table 6.7.16.  In case of reinforced brickwork, the
thickness of joints containing steel bars shall be increased so as to have a
minimum mortar cover of 6 mm around the bar. In bands of reinforced
brickwork, the area of steel provided shall be equal to that specified above for
reinforced concrete bands.
Table 6.7.16: Band Reinforcement

Seismic
Zones
Plain Mild Steel Bars
High Strength
Deformed Bars
Links
2, 3
2 - 12 mm dia, one on
each face of the wall with
suitable cover
2 - 10 mm dia, one on
each face of the wall
with suitable cover
6 mm dia, 150 mm
c/c
2 - 16 mm dia, one on
each face of the wall with
suitable cover
2 - 12 mm dia, one on
each face of the wall
with suitable cover
6 mm dia, 150 mm
c/c

7.8.6.4
Strengthening of corner and junctions
Vertical steel at corners and junctions of walls which are up to one and a half
bricks thick shall be provided either with mild steel or high strength deformed
bars as specified in Table 6.7.17. For thicker walls, reinforcement shall be
increased proportionately. The reinforcement shall be properly embedded in
the plinth masonry of foundations and roof slab or roof band so as to develop its
tensile strength in bond and passing through the lintel bands in all storeys. Bars
in different storeys may be welded or suitably lapped.
(a) Typical details of vertical steel in brickwork and hollow block at corners,
T-junctions and jambs of opening are shown in Figures 6.7.1 and 6.7.2.
(b) Details of vertical reinforcement given in Table 6.7.17 are applicable to
brick masonry and hollow block masonry.
7.8.6.5
Strengthening  of jambs of openings
Openings in bearing walls shall be strengthened, where necessary, by providing
reinforced concrete members or reinforcing the brickwork around them as
shown in Figure 6.7.3.
7.8.6.6
Walls adjoining structural framing
Where walls are dependent on the structural frame for lateral support they shall
be anchored to the structural members with metal ties or keyed to the
structural members. Horizontal ties shall consist of 6 mm diameter U-bars
spaced at a maximum of 450 mm on centre and embedded at least 250 mm into
the masonry and properly tied to the vertical steel of the same member.
Table 6.7.17: Vertical Reinforcement for Brick and Hollow Block Masonry
No. of
Storeys
Storeys
Diameter of Single Bar or
Equivalent Area of Plain Mild
Steel Bar to be Provided
(mm)
Diameter of Single Bar or
Equivalent Area of High Strength
Deformed Bar to be Provided
(mm)
Zone 2 and 3
Zone 4
Zone 2 and 3
Zone 4
------

nil
nil
Top
Bottom
nil
nil
nil
nil
Top
Middle
Bottom
Top
Third
Second
Bottom

| No. of Storeys<br />Storeys                   | Diameter of Single Bar or<br />Equivalent Area of Plain Mild<br />Steel Bar to be Provided<br />(mm) | Diameter of Single Bar or<br />Equivalent Area of High Strength<br />Deformed Bar to be Provided<br />(mm) |
| --------------------------------------------- | ---------------------------------------------------------------------------------------------------- | ---------------------------------------------------------------------------------------------------------- |
| No. of<br />Storeys<br />Storeys              | Zone 2 and 3<br />Zone 4                                                                             | Zone 2 and 3<br />Zone 4                                                                                   |
| 1 <br />-                                     | nil<br />12                                                                                          | nil<br />10                                                                                                |
| 2 <br />Top<br />Bottom                       | nil<br />nil<br />12<br />16                                                                         | nil<br />nil<br />10<br />12                                                                               |
| 3 <br />Top<br />Middle<br />Bottom           | 12<br />12<br />16<br />12<br />16<br />16                                                           | 10<br />10<br />12<br />10<br />12<br />12                                                                 |
| 4<br />Top<br />Third<br />Second<br />Bottom | 12<br />12<br />16<br />16<br />12<br />16<br />20<br />25                                           | 10<br />10<br />12<br />12<br />10<br />12<br />16<br />20                                                 |

Figure 6.7.1 Typical details of vertical reinforcement in brick masonry

Figure 6.7.2 Typical details of vertical reinforcement in hollow block masonry

Figure 6.7.3 Minimum reinforcement in walls and around openings in Seismic Zones 2, 3 and 4

7.9
Provisions For High Wind Regions
7.9.1
General
The provisions of this Section shall apply to masonry structures located at
regions where the basic wind speed is greater than 200 km/h.
7.9.2
Materials
Materials for masonry structures shall generally comply with the provisions of
Part 5; however, there are some special requirements for masonry construction
in high wind regions, which are given below:
(a) Burnt clay bricks shall have a compressive strength not less than 15
N/mm2,
(b) Grout shall have a minimum compressive strength of 12.5 N/mm2,
(c) Mortar for exterior walls and interior shear walls shall be type M1 or M2,
(d) Unburnt clay masonry units shall not be used.
7.9.3
Construction Requirements
Masonry construction shall comply with the provisions of Sec 7.10.
7.9.4
Foundation
Footings shall have a thickness of not less than 375 mm and shall be extended
450 mm below the undisturbed ground surface. Foundation stem wall shall
have the same width and reinforcement as the wall it supports.
7.9.5
Drainage
Walls retaining more than 1 m of earth and enclosing interior spaces or floors
below grade shall have minimum 100 mm diameter footing drain. A slope of
1:50 away from the building shall be provided around the building.
7.9.6
Wall Construction

##### 7.9.6.1 Minimum thickness of different types of wall shall be as given in Table

6.7.18.

##### 7.9.6.2 All walls shall be laterally supported at the top and bottom. The

maximum unsupported height of bearing walls or other masonry walls shall be

### 3.5 m. Gable end walls may be 4.5 m high at their peak.

##### 7.9.6.3  The span of lintels over openings shall not exceed 3.5 m. All lintels shall

be reinforced and the reinforcement bars shall extend not less than 600 mm
beyond the edge of opening and into lintel supports.

7.9.6.4
Walls shall be adequately reinforced.

##### 7.9.6.5 Anchors between walls and floors or roofs shall be embedded in

grouted cells or cavities and shall conform to Sec 7.9.7 below.
Table 6.7.18: Minimum thickness of Walls in High Wind Region
Type of Wall
Minimum Thickness (mm)
Unreinforced grouted brick wall
Reinforced exterior bearing wall
Unreinforced hollow and solid masonry wall
Interior nonbearing wall
7.9.7
Floor and Roof Systems
Floors and roofs of all masonry structures shall be adequately anchored with
the wall it supports to resist lateral and uplift forces due to wind specified in Sec

### 2.4 of this Part.

7.9.8
Lateral Force Resistance

##### 7.9.8.1 Strapping, approved framing anchors and mechanical fasteners, bond

beams and vertical reinforcement shall be installed to provide a continuous tie
from the roof to foundation system as shown in Figure 6.7.4. In addition, roof
and floor systems, masonry shear walls, or masonry or wood cross walls shall
be provided for lateral stability.

##### 7.9.8.2 Floor and roof diaphragms shall be properly connected to masonry

walls. Gable and sloped roof members not supported at the ridge shall be tied by
the ceiling joist or equivalent lateral ties located  as close to where the roof
members bear on the wall as practically possible and  not at  more than 1.2 m on
centers. Collar ties shall not be used for these lateral ties.

##### 7.9.8.3 Masonry walls shall be provided around all sides of floor and roof

systems in accordance with Figure 6.7.5. The cumulative length of exterior
masonry walls along each side of the floor or roof systems shall be at least 20
percent of the parallel dimension. Required elements shall be without openings
and shall not be less that 1.25 m in width.
Interior cross walls at right angles to bearing walls shall be provided when the
length of the building perpendicular to the span of the floor of roof framing
exceeds twice the distance between shear walls or 10 m, whichever is greater.

##### 7.9.8.4 When required interior cross wall shall be at least 1.8 m long and

reinforced with 2 mm wire joint reinforcement spaced not  more than 400 mm
on centre.

Figure 6.7.4 Continuous tie from roof to foundation of masonry structure

Figure 6.7.5 Masonry walls required in high wind regions
7.10
Construction

#### 7.10.1 General

Masonry shall be constructed according to the provisions of this Section.

#### 7.10.2 Storage and Preparation of Construction Materials

Storage, handling and preparation at the site shall conform to the following:
(a) Masonry materials shall be stored in such a way that at the time of
use the materials are clean and structurally suitable for the intended
use.
(b) All metal reinforcement shall be free from loose rust and other
coatings that inhibit reinforcing bond.
(c) Burnt clay units shall have a rate of absorption per minute not
exceeding 1 litre/m2 at the time of lying. In the absorption test the
surface of the unit shall be held 3 mm below the surface of the water.
(d) Burnt clay units shall be thoroughly wetted before placing. Concrete
masonry units shall not be wetted unless otherwise approved.
(e) Materials shall be stored in such a manner that deterioration or
intrusion of foreign materials is prevented and at the time of mixing
the material conforms to the applicable requirements.
(f)
The method of measuring materials for mortar and grout shall be
such that proportions of the materials can be easily controlled.

(g) Mortar or grout mixed at the job site shall be mixed for a period of
time not less than 3 minutes or more than 10 minutes in a mechanical
mixer with the amount of water required to provide the desired
workability. Hand mixing of small amounts of mortar is permitted.
Mortar may be retempered. Mortar or grout which has hardened or
stiffened due to hydration of the cement shall not be used, but  under
no case shall mortar be used two and one-half hours, nor grout used
one and one-half hours, after the initial mixing water has been added
to the dry ingredients at the job site.

#### 7.10.3 Placing Masonry Units

(a) The mortar shall be sufficiently plastic and units shall be placed with
sufficient pressure to extrude mortar from the joint and produce a
tight joint. Deep furrowing which produces voids shall not be used.
The initial bed joint thickness shall not be less than 5 mm or more
than 25 mm; subsequent bed joints shall be not less than 5 mm or
more than 15 mm in thickness.
(b) All surfaces in contact with mortar or grout shall be clean and free of
deleterious materials.
(c) Solid masonry units shall have full head and bed joints.
(d) All head and bed joints shall be filled solidly with mortar for a
distance from the face of the unit not less than the thickness of the
shell. Head joints of open-end units with beveled ends need not be
mortared. The beveled ends shall form a grout key which permits
grout within 16 mm of the face of the unit. The units shall be tightly
butted to prevent leakage of grout.

#### 7.10.4 Verticality and Alignment

All masonry shall be built true and plumb within the tolerances prescribed
below. Care shall be taken to keep the perpends properly aligned.
(a) Deviation from vertical within a storey shall not exceed 6 mm per 3m
height.
(b) Deviation in verticality in total height of any wall of a building more
than one storey in height shall not exceed 12 mm.
(c) Deviation from position shown on plan of any brickwork shall not
exceed 12 mm.
(d) Relative displacement between load bearing walls in adjacent storeys
intended to be in vertical alignment shall not exceed 6 mm.
(e) Deviation of bed joint from horizontal in a length of 12 m shall not
exceed 6 mm subject to a maximum deviation of 12 mm.
(f)
Deviation from the specified thickness of bed joints, cross joints and
perpends shall not exceed one-fifth of the specified thickness.

#### 7.10.5 Reinforcement Placing

Reinforcing details shall conform to the requirements of Sec 7.6.6. Metal
reinforcement shall be located in accordance with the plans and specifications.
Reinforcement shall be secured against displacement prior to grouting by wire
positioners or other suitable devices at intervals not exceeding 20 bar
diameters.
Tolerances for the placement of steel in walls and flexural elements shall be ±12
mm for 0 ≤200 mm, ±25 mm for 200 mm ≤0 ≤600 mm and ± 30 mm for 0 >
600 mm. Tolerance for longitudinal location of reinforcement shall be ± 50 mm.

#### 7.10.6 Grouted Masonry

Grouted masonry shall be constructed in such a manner that all elements act
together as a structural element.
Space to be filled with grout shall be clean and shall not contain any foreign
materials. Grout materials and water content shall be controlled to provide
adequate workability and shall be mixed thoroughly. The grouting of any section
of wall shall be completed in one day with no interruptions greater than one hour.
Size and height limitations of the grout space or cell shall not be less than those
shown in Table 6.7.19.  Higher grout pours or smaller cavity widths or cell size
than shown in Table 6.7.19 may be used when approved, if it can be
demonstrated that grout spaces are properly filled.
Cleanouts are required for all grout pours over 1.5 m in height. When required,
cleanouts shall be provided in the bottom course at every vertical bar but shall
not be spaced more than 800 mm on centre for solidly grouted masonry. When
cleanouts are required, they shall be sealed after inspection and before grouting.
When cleanouts are not provided, special provisions must be made to keep the
bottom and sides of the grout spaces, as well as the minimum total clear area as
required by Table 6.7.19, clean and clear prior to grouting.
Table 6.7.19: Grouting Limitations

Grout
Type
Grout pour
Maximum
Height (m)
Minimum Dimensions of the Total Clear Areas
within Grout Spaces and Cells
Multi-wythe
Masonry  (mm)
Hollow Unit
Masonry (mm )
Fine
0.30
1.50
2.40
3.65
7.30
4050
4050
4075
4575
7575
Coarse
0.30
1.50
2.40
3.65
7.30
4075
6075
7575
7575
75100

| Grout<br />Type | Grout pour<br />Maximum<br />Height (m)      | Minimum Dimensions of the Total Clear Areas<br />within Grout Spaces and Cells | Col4                                               |
| --------------- | -------------------------------------------- | ------------------------------------------------------------------------------ | -------------------------------------------------- |
| Grout<br />Type | Grout pour<br />Maximum<br />Height (m)      | Multi-wythe<br />Masonry  (mm)                                                 | Hollow Unit<br />Masonry (mm)                      |
| Fine            | 0.30<br />1.50<br />2.40<br />3.65<br />7.30 | 20<br />40<br />40<br />40<br />50                                             | 4050<br />4050<br />4075<br />4575<br />7575  |
| Coarse          | 0.30<br />1.50<br />2.40<br />3.65<br />7.30 | 40<br />50<br />50<br />60<br />75                                             | 4075<br />6075<br />7575<br />7575<br />75100 |

#### 7.10.7 Chases, Recesses and Holes

(a) Chases, recesses and holes may be permitted in masonry provided
either they are considered in the structural design or they are not cut
into walls made of hollow or perforated units, or vertical chases  are
planned instead of horizontal chases.
(b) Depth of vertical and horizontal chases in load bearing walls shall not
exceed one-third and one-sixth of the wall thickness respectively.
(c) Vertical chases shall not be closer than 2 m in any stretch of wall and
shall not be located within 350 mm of an opening or within 230 mm
of a cross wall that serves as stiffening wall for stability. Width of a
vertical chase shall not exceed the thickness of wall in which it occurs.
(d) Horizontal chases shall be located in the upper or lower middle third
height of wall at a distance not less than 600 mm from lateral
support. No horizontal chase shall exceed one metre in length and
there shall not be more than 2 chases in any one wall. Horizontal
chases shall have minimum mutual separation distance of 500 mm.
Sum of lengths of all chases and recesses in any horizontal plane shall
not exceed one-fourth the length of the wall.
(e) Lintel shall not be used to support masonry directly above a recess or
a hole wider than 300 mm.  No lintel however, is necessary in case of
a circular recess or hole exceeding 300 mm in diameter provided
upper half of the recess or hole is built as a semi-circular arch of
adequate thickness and there is adequate length of masonry on the
sides of openings to resist the horizontal thrust.
(f)
Recesses and holes in masonry shall be kept at the time of
construction so as to avoid subsequent cutting. If cutting is necessary,
it shall be done using sharp tools without causing heavy impact and
damage to the surrounding areas.
(g) No chase, recess or hole shall be provided in half-brick load bearing
wall, excepting the minimum number of holes needed for scaffolding.

### 7.11 Confined Masonry

#### 7.11.1 General

Confined masonry construction consists of masonry walls (made either of clay
brick or concrete block units) and horizontal and vertical RC confining members
built on all four sides of a masonry wall panel. Vertical members, called tie-
columns or practical columns, resemble columns in RC frame construction
except that they tend to be of far smaller cross-section. Horizontal elements,
called tie-beams, resemble beams in RC frame construction. To emphasize that
confining elements are not beams and columns, alternative terms horizontal ties
and vertical ties could be used instead of tie-beams and tie-columns.

The confining members are effective in
(a) Enhancing the stability and integrity of masonry walls for in-plane and
out-of-plane earthquake loads (confining members can effectively
contain damaged masonry walls),
(b) Enhancing the strength (resistance) of masonry walls under lateral
earthquake loads, and
(c) Reducing the brittleness of masonry walls under earthquake loads and
hence improving their earthquake performance.
The structural components of a confined masonry building are (see Figure 6.7.6):
(a) Masonry walls – transmit the gravity load from the slab(s) above down
to the foundation. The walls act as bracing panels, which resist
horizontal earthquake forces. The walls must be confined by concrete
tie-beams
and
tie-columns
to
ensure
satisfactory
earthquake
performance.
(b) Confining elements (tie-columns and tie-beams) - provide restraint to
masonry walls and protect them from complete disintegration even in
major earthquakes.
These elements resist gravity loads and have important role in ensuring vertical
stability of a building in an earthquake.
(a) Floor and roof slabs - transmit both gravity and lateral loads to the
walls. In an earthquake, slabs behave like horizontal beams and are
called diaphragms.
(b) Plinth band - transmits the load from the walls down to the foundation.
It also protects the ground floor walls from excessive settlement in soft
soil conditions.
(c) Foundation - transmits the loads from the structure to the ground.
The design of confined masonry members shall be based on similar
assumptions to those set out for unreinforced and for reinforced masonry
members. Confined masonry shall be constructed according to the
provisions of this Section.

Figure 6.7.6 Typical confined masonry building

#### 7.11.2 Difference of Confined Masonry from RC Frame Construction

The appearance of a finished confined masonry construction and a RC frame
construction with masonry in fills may look alike, however these two
construction systems are substantially different. The main differences are
related to the construction sequence, as well as to the manner in which these
structures resist gravity and lateral loads. These differences are summarized in
Table 6.7.20 and are illustrated by diagrams in Figure 6.7.7.
In confined masonry construction, confining elements are not designed to act as
a moment-resisting frame; as a result, detailing of reinforcement is simple. In
general, confining elements have smaller cross-sectional dimensions than the
corresponding beams and columns in a RC frame building. It should be noted
that the most important difference between the confined masonry walls and
infill walls is that infill walls are not load-bearing walls, while the walls in a
confined masonry building are.
A transition from RC frame to confined masonry construction in most cases
leads to savings related to concrete cost, since confining elements are smaller in
size than the corresponding RC frame members.
Table 6.7.20: Comparison between confined masonry and RC frame construction
Component
Confined masonry construction
RC frame construction
Gravity and
lateral load-
resisting
system
Masonry walls are the main load
bearing elements and are expected
to resist both gravity and lateral
loads. Confining elements (tie-
beams
and
tie-columns)
are
significantly smaller in size than
RC beams and columns.
RC frames resist both gravity
and lateral loads through
their relatively large beams,
columns,
and
their
connections. Masonry in fills
are not load-bearing walls.
Foundation
construction
Strip footing beneath the wall and
the RC plinth band
Isolated footing beneath each
column
Superstructure
construction
sequence

1. Masonry walls are constructed
   first.
2. Subsequently, tie-columns are
   cast in place.
3. Finally,
   tie-beams
   are
   constructed on top of the walls,
   simultaneously
   with
   the
   floor/roof slab construction.
4. The frame is constructed
   first.
5. Masonry
   walls
   are
   constructed at a later stage
   and are not bonded to the
   frame
   members;
   these
   walls are nonstructural,
   that is, non-load bearing
   walls.

| Component                                                 | Confined masonry construction                                                                                                                                                                                                                                         | RC frame construction                                                                                                                                                                                                                                                                 |
| --------------------------------------------------------- | --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| Gravity and<br />lateral load-<br />resisting<br />system | Masonry walls are the main load<br />bearing elements and are expected<br />to resist both gravity and lateral<br />loads. Confining elements (tie-<br />beams<br />and<br />tie-columns)<br />are<br />significantly smaller in size than<br />RC beams and columns. | <br /> <br /> <br /> <br /> <br />RC frames resist both gravity<br />and lateral loads through<br />their relatively large beams,<br />columns,<br />and<br />their<br />connections. Masonry in fills<br />are not load-bearing walls.                                               |
| Foundation<br />construction                              | Strip footing beneath the wall and<br />the RC plinth band                                                                                                                                                                                                            | <br />Isolated footing beneath each<br />column                                                                                                                                                                                                                                       |
| Superstructure<br />construction<br />sequence            | 1. Masonry walls are constructed<br />first.<br />2. Subsequently, tie-columns are<br />cast in place.<br />3. Finally,<br />tie-beams<br />are<br />constructed on top of the walls,<br />simultaneously<br />with<br />the<br />floor/roof slab construction.       | <br /> <br /> <br /> <br />1. The frame is constructed<br />first.<br />2.  Masonry<br />walls<br />are<br />constructed at a later stage<br />and are not bonded to the<br />frame<br />members;<br />these<br />walls are nonstructural,<br />that is, non-load bearing<br />walls. |

#### 7.11.3 Mechanism of Resisting Earthquake Effects

A confined masonry building subjected to earthquake ground shaking can be
modeled as a vertical truss, as shown in Figure 6.7.8. Masonry walls act as
diagonal struts subjected to compression, while reinforced concrete confining
members act in tension and/or compression, depending on the direction of
lateral earthquake forces. This model is appropriate before the cracking in the
walls takes place. Subsequently, the cracking is concentrated at the ground floor
level and significant lateral deformations take place. Under severe earthquake
ground shaking, the collapse of confined masonry buildings may take place due
to soft storey effect similar to the one observed in RC frames with masonry in
fills, as shown in Figure 6.7.8. The following failure modes are characteristic of
confined masonry walls:
(a) Shear failure mode, and; (b) Flexural failure mode.
Note that, in confined masonry structures, shear failure mode develops due to
in-plane seismic loads (acting along in the plane of the wall), whereas flexural
failure mode may develop either due to in-plane or out-of-plane loads (acting
perpendicular to the wall plane).
Shear failure mode is characterized by distributed diagonal cracking in the wall.
These cracks propagate into the tie-columns at higher load levels, as shown in
Figure 6.7.9. Initially, a masonry wall panel resists the effects of lateral
earthquake loads by itself while the confining elements (tie-columns) do not
play a significant role. However, once the cracking takes place, the wall pushes
the tie-columns sideways. At that stage, vertical reinforcement in tie-columns
becomes engaged in resisting tension and compression stresses. Damage in the
tie-columns at the ultimate load level is concentrated at the top and the bottom
of the panel. These locations, characterized by extensive crushing of concrete
and yielding of steel reinforcement, are called plastic hinges (Figure 6.7.10).
Note that the term plastic hinge has a different meaning in the context of
confined masonry components than that referred to in relation to RC beams and
columns, where these hinges form due to flexure and axial loads. In confined
masonry construction, tie-beams and tie-columns resist axial loads. Shear
failure can lead to severe damage in the masonry wall and the top and bottom of
the tie-columns.

(a)
(b)
Figure 6.7.7 (a) RC frame construction; (b) Confined masonry construction

(a)
(b)
Figure 6.7.8  Confined masonry building: (a) Vertical truss model; (b) Collapse at the
ground floor level

Figure 6.7.9 Shear failure of
confined masonry walls
Figure 6.7.10 Plastic hinge developed in a confined
masonry wall
Flexural failure caused by in-plane lateral loads is characterized by horizontal
cracking in the mortar bed joints on the tension side of the wall, as shown in
Figure 6.7.11. Extensive horizontal cracking, which usually takes place in tie-
columns, as well as shear cracking can be observed.
Irrespective of the failure mechanism, tie-columns resist the major portion of
gravity load when masonry walls suffer severe damage (this is due to their high
axial stiffness and load resistance). The failure of a tie- column usually takes
place when cracks propagate from the masonry wall into the tie-column and
shear it off. Subsequently, the vertical stability of the entire wall is
compromised. Vertical strains in the confined masonry walls decrease at an
increased damage level, thereby indicating that a major portion of the gravity
load is resisted by tie-columns. This finding confirms the notion that tie-
columns have a critical role in resisting the gravity load in damaged confined
masonry buildings and ensuring their vertical stability.

#### 7.11.4 Key Factors Influencing Seismic Resistance

##### 7.11.4.1 Wall density

Wall density is believed to be one of the key parameters influencing the seismic
performance of confined masonry buildings. It can be determined as the
transverse area of walls in each principal direction divided by the total floor
area of the building.

##### 7.11.4.2 Masonry units and mortar

The lateral load resistance of confined masonry walls strongly depends on the
strength of the masonry units and the mortar used. The walls built using low-
strength bricks or ungrouted hollow block units had the lowest strength while
the ones built using grouted or solid units had the largest strength. However, the
use of grouted and solid units results in an increase both in wall mass and
seismic loads. Also, the weaker the mortar the lower the masonry strength (due
to the unit-mortar interaction, the masonry strength is always lower than the
unit strength). There is no significant difference in strength between
unreinforced and confined masonry wall specimens with the same geometry
and material properties.

##### 7.11.4.3 Tie-columns

Tie-columns significantly influence the ductility and stability of cracked
confined masonry walls. The provision of closely spaced transverse
reinforcement (ties) at the top and bottom ends of tie-columns results in
improved wall stability and ductility in the post-cracking stage.

##### 7.11.4.4 Horizontal wall reinforcement

Horizontal reinforcement has a beneficial effect on wall ductility. Specimens
with horizontal reinforcement showed a more uniform distribution of inclined
shear cracks than the unreinforced specimens. Horizontal rebars should be
anchored into the tie-columns; the anchorage should be provided with 900
hooks at the far end of the tie-column (Figure 6.7.12). The hooks should be
embedded in the concrete within the tie-column (note that the tie-column
reinforcement was omitted from the figure). The bar diameter should be larger
than 3.5 mm and less than ¾ the joint thickness.

##### 7.11.4.5 Openings

When the opening area is less than approximately 10 percent of the total wall
area, the wall lateral load resistance is not significantly reduced as compared to
a solid wall (i.e. wall without openings). The walls with larger openings develop
diagonal cracks (same as solid walls), except that the cracks are formed in the
piers between the openings; thus, diagonal struts form in the piers, as shown in
Figure 6.7.13.

#### 7.11.5 Verification of Members

7.11.5.1
In the verification of confined masonry members subjected to
bending and/or axial loading, the assumptions for reinforced masonry members
should be adopted. In determining the design value of the moment of resistance
of a section a rectangular stress distribution may be assumed, based on the
strength of the masonry, only. Reinforcement in compression should also be
ignored.
7.11.5.2
In the verification of confined masonry members subjected to shear
loading the shear resistance of the member should be taken as the sum of the
shear resistance of the masonry and of the concrete of the confining elements. In
calculating the shear resistance of the masonry the rules for unreinforced
masonry walls subjected to shear loading should be used, considering the length
of the masonry element. Reinforcement of confining elements should not be
taken into account.
7.11.5.3
In the verification of confined masonry members subjected to lateral
loading, the assumptions set out for unreinforced and reinforced masonry walls
should be used. The contribution of the reinforcement of the confining elements
should be considered.

Figure 6.7.11 Flexural failure of
confined masonry walls
Figure 6.7.12 Horizontal reinforcement in
confined masonry walls

Figure 6.7.13 Failure modes in the confined masonry walls with openings

#### 7.11.6 Confined Masonry Members

##### 7.11.6.1 Confined masonry members shall not exhibit flexural cracking nor

deflect excessively under serviceability loading conditions.

##### 7.11.6.2 The verification of confined masonry members at the serviceability

limit states shall be based on the assumptions given for unreinforced masonry
members.

#### 7.11.7 Architectural Guideline

##### 7.11.7.1 Building Layout

(a) The building should not be excessively long relative to its width; ideally,
the length-to-width ratio should not exceed 4.
(b) The walls should be continuous up the building height.
(c) Openings (doors and windows) should be placed in the same position up
the building height.

##### 7.11.7.2 Walls

(a) At least two fully confined walls should be provided in each direction.
(b) For Seismic Zone 1 and 2, wall density of at least 2 percent in each of two
orthogonal directions is required to ensure good earthquake performance
of confined masonry construction. The wall density for Seismic Zones 3 and
4 should be at least 4 percent and 5 percent respectively. Wall density can
be defined as the total cross sectional area of all walls in one direction
divided by the sum of the floor plan areas for all floors in a building.

##### 7.11.7.3 Building Height

Confined masonry is suitable for low- to medium-rise building construction.
Confined masonry buildings will be subject to the following height restrictions:
(a) Up to 4-storey high for Seismic Zone 1 and 2
(b) Up to 3-storey high for Seismic Zone 3
(c) Up to 2-storey high for Seismic Zone 4

#### 7.11.8 Confined Masonry Details

7.11.8.1
Confined masonry walls shall be provided with vertical and
horizontal reinforced concrete or reinforced masonry confining elements so
that they act together as a single structural member.
7.11.8.2
Top and sides confining elements shall be cast after the masonry has
been built so that they will be duly anchored together.

##### 7.11.8.3 Vertical confining elements should be placed:

(a) at the free edges of each structural wall element;
(b) at both sides of any wall opening with an area of more than 1.5 m2;
(c) within the wall if necessary in order not to exceed a spacing of 5 m between
the confining elements;
(d) at the intersections of structural walls, wherever the confining elements
imposed by the above rules are at a distance larger than 1.5 m.
7.11.8.4
Horizontal confining elements shall be placed in the plane of the wall
at every floor level and in any case with a vertical spacing of not more than 4 m.
7.11.8.5
Confining elements should have a cross-sectional area not less than

### 0.02 m2, with a minimum dimension of 150 mm in the plan of the wall. In

double-leaf walls the thickness of confining elements should assure the
connection of the two leaves and their effective confinement.
7.11.8.6
The longitudinal reinforcement of confining elements may not have a
cross-sectional area less than 300 mm2, nor than 1 percent of the cross-sectional
area of the confining element. The detailing of the reinforcements should be in
accordance with Chapter 8.
7.11.8.7
Stirrups not less than 6 mm in diameter and spaced not more than
300 mm should be provided around the longitudinal reinforcement. Column ties
should preferably have 135° hooks – the use of 90° hooks is not recommended.
At a minimum, 6 mm ties at 200 mm spacing (6 mm\@200 mm) should be
provided. It is recommended to use 6 mm ties at 100 mm spacing (6 mm\@100
mm) in the column end-zones (top and bottom).
7.11.8.8
To ensure the effectiveness of tie-beams in resisting earthquake
loads, longitudinal bars should have a 90° hooked anchorage at intersections, as
shown in Figure 6.7.14. The hook length should be at least 500 mm.
7.11.8.9
Proper detailing of the tie-beam-to-tie-column connections is a must
for satisfactory earthquake performance of the entire building. Reinforcing bars
must be properly anchored. A typical connection detail at the roof level is shown
in Figure 6.7.15. Note that the tie-column reinforcement needs to be extended
into the tie-beam as much as possible, preferably up to the underside of the top
tie-beam reinforcement. A hooked anchorage needs to be provided (90° hooks)
both for the tie-column and tie-beam reinforcement.

##### 7.11.8.10 Special lintel beams may be required across larger openings having a

width exceeding 1.5 m. Additional reinforcement bars need to be provided.
Lintel beams can be integrated with the tie-beams at the floor level.

##### 7.11.8.11 Lap splices may not be less than 60 bar diameters or 500 mm in

length. Splicing should take place at column mid height, except for the ground
floor level (where splicing is not permitted).

##### 7.11.8.12 The minimum wall thickness should not be less than 100 mm. The

wall height/thickness ratio should not exceed 30.

##### 7.11.8.13 Toothed edges should be left on each side of the wall, as shown in

Figure 6.7.16(a). Toothed edges are essential for adequate wall confinement,
which contributes to satisfactory earthquake performance. Alternatively, when
the interface between the masonry wall and the concrete tie-column needs to
ৎবসধরহ ংসড়ড়ঃয ভড়ৎ ধঢ়ঢ়বধৎধহপব্থং ংধশব, ংঃববষ ফড়বিষং ংযড়ঁষফ নব ঢ়ৎড়ারফবফ রহ
mortar bed joints to ensure interaction between the masonry and the concrete
during an earthquake, Figure 6.7.16(b).

##### 7.11.8.14 Concrete in the tie-columns can be poured once the desired wall

height has been reached. The masonry walls provide formwork for the tie-
columns on two sides; however the formwork must be placed on the remaining
two sides.

#### 7.11.9 Foundation and Plinth Construction

The foundation should be constructed as in traditional brick masonry
construction. Either an uncoursed random rubble stone masonry footing or a RC
strip footing can be used. A RC plinth band should be constructed on top of the
foundation. In confined masonry construction, plinth band is essential for
preventing building settlements in soft soil areas. An alternative foundation
solution with RC strip footing is also illustrated in Figure 6.7.17.

(a)
(b)
Figure 6.7.14 Tie-beam construction: (a) Wall intersections; (b) Hooked anchorage to
longitudinal reinforcement

Figure 6.7.15: Detailing requirement for the tie-beam-to-tie-column connection

(a)

(b)
Figure 6.7.16 (a) Toothed wall construction; (b) Horizontal dowels at the wall-to-
column interface

(a)

(b)
Figure 6.7.17 Foundation construction: (a) RC plinth band and stone masonry
foundation; (b) RC strip footing